IEC 60137:2008

IEC 60137:2008

July 2008
International standard Cancelled

Insulated bushings for alternating voltages above 1 000 V

IEC 60137:2008 gives the characteristics and tests for insulated bushings intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This edition includes the following significant technical changes with respect to the previous edition:- Long duration power-frequency for transformer bushings;- Special requirements for type and acceptance tests applicable to transformer and GIS bushings;- Specific insulation levels for bushings fitted to transformers and GIS;- According to IEC Guide 111, clauses relating to safety and the environment have been added; and- The altitude correctino procedure has been revised (> 1 000 m).

Main informations

Collections

International IEC standards

Publication date

July 2008

Number of pages

115 p.

Reference

IEC 60137:2008

Print number

6 - 19/08/2008
Sumary
Insulated bushings for alternating voltages above 1 000 V

IEC 60137:2008 gives the characteristics and tests for insulated bushings intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This edition includes the following significant technical changes with respect to the previous edition:
- Long duration power-frequency for transformer bushings;
- Special requirements for type and acceptance tests applicable to transformer and GIS bushings;
- Specific insulation levels for bushings fitted to transformers and GIS;
- According to IEC Guide 111, clauses relating to safety and the environment have been added; and
- The altitude correctino procedure has been revised (> 1 000 m).
Replaced standards (1)
IEC 60137:2003
August 2003
International standard Cancelled
Insulated bushings for alternating voltages above 1000 V

Specifies the characteristics and tests for insulated bushings intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings.

Standard replaced by (1)
IEC 60137:2017
June 2017
International standard Current
Insulated bushings for alternating voltages above 1000 V

IEC 60137:2017 specifies the characteristics and tests for insulated bushings. This standard is applicable to bushings, as defined in Clause 3, intended for use in electrical apparatus, machinery, transformers, switchgear and installations for three-phase alternating current systems, having highest voltage for equipment above 1 000 V and power frequencies of 15 Hz up to and including 60 Hz. Subject to special agreement between purchaser and supplier, this standard may be applied, in part or as a whole, to the following: - bushings used in other than three-phase systems; - bushings for high-voltage direct current systems; - bushings for testing transformers; - bushings for capacitors. Special requirements and tests for transformer bushings in this standard apply also to reactor bushings. This standard is applicable to bushings made and sold separately. Bushings which are a part of an apparatus and which cannot be tested according to this standard should be tested with the apparatus of which they form part. This edition includes the following significant technical changes with respect to the previous edition: - Resin-impregnated synthetic (RIS) bushings has been introduced. - Bushings with Um ≤ 1,1 kV, Um = 1100 kV and Um = 1200 kV have been introduced. - Temperature rise testing has been included for liquid-insulated bushings according to clause to 3.4. - Introducing dry lightning impulse testing as a routine test for all transformer bushings with Um > 72,5 kV. - The altitude correction procedure has been revised ( > 1 000 m). - An explanation about Very Fast Transient (VFT) phenomenon and its impact on bushings has been included. The contents of the corrigendum of May 2018 have been included in this copy.