Series capacitors for power systems - Part 3: Internal fuses

Concerns internal fuses designed to isolate faulty capacitor elements, to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank, or any part thereof.This standard cancels and replaces IEC 60595 (1977)

Main informations

Collections

International IEC standards

Publication date

January 1998

Number of pages

23 p.

Reference

IEC 60143-3:1998

Print number

1 - 13/06/2005
Sumary
Series capacitors for power systems - Part 3: Internal fuses

Concerns internal fuses designed to isolate faulty capacitor elements, to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank, or any part thereof. This standard cancels and replaces IEC 60595 (1977)
Replaced standards (3)
International standard Cancelled
Amendment 1 - Internal fuses for series capacitors

IEC 60595:1977
January 1977
International standard Cancelled
Internal fuses for series capacitors

Uniform requirements regarding performance and testing, guide for co-ordination of fuse protection and test procedures for the disconnecting test on internal fuses. Note: - Applies to internal fuses used to protect series capacitors for power systems in accordance with IEC 143.

International standard Cancelled
Amendment 2 - Internal fuses for series capacitors

Standard replaced by (1)
IEC 60143-3:2015
June 2015
International standard Current
Series capacitors for power systems - Part 3: Internal fuses

IEC 60143-3:2015 applies to internal fuses designed to isolate faulty capacitor elements, to allow operation of the remaining parts of that capacitor unit and the bank in which the capacitor unit is connected. Such fuses are not a substitute for a switching device such as a circuit-breaker, or for external protection of the capacitor bank, or any part thereof. The object of this part of IEC 60143 is: - to formulate requirements regarding performance and testing; - to provide a guide for coordination of fuse and bank protection. This second edition cancels and replaces the first edition published in 1998. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: The test procedure has been largely simplified. Keywords: faulty capacitor elements, fuse and bank protection