IEC 60172:2015

IEC 60172:2015

May 2015
International standard Cancelled

Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires

IEC 60172:2015 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. This fourth edition cancels and replaces the third edition published in 1987, Amendment 1:1997 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- Revision of Clause 1, Scope, to incorporate appropriate text from former Clause 2, Object;- Deletion of Clause 2, Object, by placement of its text into existing clauses;- New Clause 2, Normative references;- Revision of 5.1.1, 5.3 and 5.4 with corrections to Amendment 2 to the third edition;- Revision of Clause 7 as to clarify which specimens comply with Table 3 and Table 4;- Revision of figures with high-resolution photos and graphs. Keywords: enamelled wire, tape wrapped round and rectangular wire, AC proof voltage tests

Main informations

Collections

International IEC standards

Publication date

May 2015

Number of pages

53 p.

Reference

IEC 60172:2015
Sumary
Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires

IEC 60172:2015 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. This fourth edition cancels and replaces the third edition published in 1987, Amendment 1:1997 and Amendment 2:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Revision of Clause 1, Scope, to incorporate appropriate text from former Clause 2, Object;
- Deletion of Clause 2, Object, by placement of its text into existing clauses;
- New Clause 2, Normative references;
- Revision of 5.1.1, 5.3 and 5.4 with corrections to Amendment 2 to the third edition;
- Revision of Clause 7 as to clarify which specimens comply with Table 3 and Table 4;
- Revision of figures with high-resolution photos and graphs. Keywords: enamelled wire, tape wrapped round and rectangular wire, AC proof voltage tests
Replaced standards (3)
IEC 60172:1987
December 1987
International standard Cancelled
Test procedure for the determination of the temperature index of enamelled winding wires

Specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled and of tape wrapped round and rectangular wire. It does not include fibre-insulated wire or wire covered with tapes containing inorganic fibres.

International standard Cancelled
Amendment 2 - Test procedure for the determination of the temperature index of enamelled winding wires

IEC 60172:1987/AMD1:1997
December 1997
International standard Cancelled
Amendment 1 - Test procedure for the determination of the temperature index of enamelled winding wires

Standard replaced by (1)
IEC 60172:2020
November 2020
International standard Current
Test procedure for the determination of the temperature index of enamelled and tape wrapped winding wires

IEC 60172:2020 specifies, in accordance with the provisions of IEC 60216-1, a method for evaluating the temperature index of enamelled wire, varnished or unvarnished with an impregnating agent, and of tape wrapped round and rectangular wire, in air at atmospheric pressure by periodically monitoring changes in response to AC proof voltage tests. This procedure does not apply to fibre-insulated wire or wire covered with tapes containing inorganic fibres. NOTE The data obtained according to this test procedure provide the designer and development engineer with information for the selection of winding wire for further evaluation of insulation systems and equipment tests. This fifth edition cancels and replaces the fourth edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - revision of 3.1, definition of thermal index; - revision of 3.3, time to failure; - revisions to 5.1.1 for clarity and to reduce the range wire size range to which the test applies; - revisions to 5.1.2 for tape wrapped round and enamelled or tape wrapped rectangular wire for clarity; - revision to Clause 9 to add the correlation coefficient, r to the report.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ