IEC 60183:1984
IEC 60183:1984

IEC 60183:1984

January 1984
International standard Cancelled

Guide to the selection of high-voltage cables

Gives guidance in the selection of the conductor size, insulation level and construction of cable to be used on three-phase alternating current systems operating at voltages exceeding 1 kV. Also summarizes the information which is necessary to enable the appropriate selection to be made.

Main informations

Collections

International IEC standards

Publication date

January 1984

Number of pages

17 p.

Reference

IEC 60183:1984

Print number

2
Sumary
Guide to the selection of high-voltage cables

Gives guidance in the selection of the conductor size, insulation level and construction of cable to be used on three-phase alternating current systems operating at voltages exceeding 1 kV. Also summarizes the information which is necessary to enable the appropriate selection to be made.
Replaced standards (1)
IEC 60183:1965
IEC 60183:1965
January 1965
International standard Cancelled
Guide to the selection of high-voltage cables

Gives guidance in the selection of the conductor size, insulation level and construction of cable to be used on three-phase alternating current systems operating at voltages exceeding 1 kV. Also summarizes the information which is necessary to enable the appropriate selection to be made.

Standard replaced by (1)
IEC 60183:2015
IEC 60183:2015
January 2015
International standard Current
Guidance for the selection of high-voltage A.C. cable systems

IEC 60183:2015 gives guidance in the selection of a.c. high-voltage cables and cable systems with extruded insulation and mainly to be used on three-phase alternating systems operating at voltages exceeding U = 1 kV (in this standard the term high voltage is used to cover any cable above 1 kV). Submarine cables are not included in the scope. Guidance is given in the selection of the conductor size, insulation level and constructional requirements of cable to be used. In addition, information necessary to enable the appropriate selection to be made is summarized. Paper insulated power cables are not considered in this standard for their selection into cable systems. However, when selecting cables with extruded insulation to be connected together with existing paper insulated cables, particular consideration for their proper compatibility, accessories and operational characteristics should be made. Environmental aspects are mentioned at the level at which they may influence the selection of high-voltage cables and their application. This third edition cancels and replaces the second edition, published in 1984, and its Amendment 1 (1990) and constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - the scope has been changed to a.c. high-voltage cables and cable systems; - guidance relates to cables with extruded insulation; - submarine cables are not covered but cables laid in water are covered; - operation of systems with special bonding of the screen is covered; - there is guidance on accessories; - environmental aspects are addressed.