IEC 60229:2007

IEC 60229:2007

October 2007
International standard Current

Electric cables - Tests on extruded oversheaths with a special protective function

Provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function.The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests and tests after installation.These tests comprise of electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation.Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations.Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use.The significant technical changes with respect to the previous edition are as follows: - The text has been modified in order to consider the function of the oversheath, irrespective of the way the metallic sheath or screen of the cable is earthed because, in some cases, the oversheath is designed to act not only as a protection against corrosion, but also to reduce the risk of degradation of the cable insulation system. This requirement may be independent of the nature of the insulation and independent of the rated voltage of the cable.- More precise wording has been introduced regarding the application of some tests (if the sheaths or foils are bonded to the oversheath or not).- The test requirements have been revised in order to be in line with the standards published after the second edition.- The pressure test at high temperature has been deleted as the requirement is specified in the relevant cable standards.- A "Guidance on tests after installation" (Annex B) has been included.

Main informations

Collections

International IEC standards

Publication date

October 2007

Number of pages

22 p.

Reference

IEC 60229:2007
Sumary
Electric cables - Tests on extruded oversheaths with a special protective function

Provides a range of tests which may be required for electric cables which have an extruded oversheath and where that oversheath performs a special protective function. The standard covers cables for use in insulated systems and in uninsulated systems. The tests are categorized for use as routine tests, type tests and tests after installation. These tests comprise of electrical routine tests on cable oversheath used in insulated or uninsulated systems, abrasion and corrosion spread type tests, electrical test on cable oversheath after installation. Routine tests and tests after installation, as specified in the relevant cable standards, are applicable for all situations. Type tests depend upon the nature of the system and the construction of the cable and do not have to be carried out for normal conditions of use. The significant technical changes with respect to the previous edition are as follows: - The text has been modified in order to consider the function of the oversheath, irrespective of the way the metallic sheath or screen of the cable is earthed because, in some cases, the oversheath is designed to act not only as a protection against corrosion, but also to reduce the risk of degradation of the cable insulation system. This requirement may be independent of the nature of the insulation and independent of the rated voltage of the cable. - More precise wording has been introduced regarding the application of some tests (if the sheaths or foils are bonded to the oversheath or not). - The test requirements have been revised in order to be in line with the standards published after the second edition. - The pressure test at high temperature has been deleted as the requirement is specified in the relevant cable standards. - A "Guidance on tests after installation" (Annex B) has been included.
Replaced standards (1)
IEC 60229:1982
January 1982
International standard Cancelled
Tests on cable oversheaths which have a special protective function and are applied by extrusion

Provides a range of tests which may be required for protective coverings consisting of extruded oversheaths when the coverings, in addition to protecting underlying metallic layers against corrosion, are required to fulfil special functions, for the following types a) and b), such as: a) insulated sheath systems: i)where special bonding is employed to reduce sheath losses, resulting in a sheath voltage under full load conditions, ii)where the cable sheath can be isolated from earth to permit a voltage to be applied to the oversheath to check the integrity of the covering. b) uninsulated sheath system: i)protection against corrosion of the underlying metal layer where preservation of the metal layer is of particular importance and/or the combination of the particular metal and the cable environment would give rise to a serious risk of corrosion. These tests are only appropriate to particular conditions and use, and do not have to be implemented for normal conditions and use. Guidance on their implementation will be provided in the relevant cable specification.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo