IEC 60255-22-6:2001

IEC 60255-22-6:2001

April 2001
International standard Cancelled

Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields

Specifies the general requirements for conducted disturbances induced by electromagnetic fields for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems.

Main informations

Collections

International IEC standards

Publication date

April 2001

Number of pages

21 p.

Reference

IEC 60255-22-6:2001

Print number

1 - 13/06/2005
Sumary
Electrical relays - Part 22-6: Electrical disturbance tests for measuring relays and protection equipment - Immunity to conducted disturbances induced by radio frequency fields

Specifies the general requirements for conducted disturbances induced by electromagnetic fields for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems.
Standard replaced by (1)
International standard Cancelled
Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirements

IEC 60255-26:2013 is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This standard specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. The requirements specified in this standard are applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only. This new edition includes the following significant technical changes with respect to the previous edition: - definition of test specifications, test procedures and acceptance criteria per phenomena and port under test in one document; - extension of radiated emission measurement for frequencies above 1 GHz; - limitation of radiated emission measurement at 3 m distance for small equipment only; - addition of zone A and zone B test level on surge test; - extension of tests on the auxiliary power supply port by a.c. and d.c. voltage dips, a.c. component in d.c. (ripple) and gradual shut-down/start-up; - harmonization of acceptance criteria for immunity tests.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ