IEC 60255-22-7:2003

IEC 60255-22-7:2003

April 2003
International standard Cancelled

Electrical relays - Part 22-7: Electrical disturbance tests for measuring relays and protection equipment - Power frequency immunity tests

Specifies general requirements for power frequency immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to short duration, conducted, common and differential mode power frequency disturbances. Is based on IEC 61000-4-16.

Main informations

Collections

International IEC standards

Publication date

April 2003

Number of pages

21 p.

Reference

IEC 60255-22-7:2003

Print number

1 - 13/06/2005
Sumary
Electrical relays - Part 22-7: Electrical disturbance tests for measuring relays and protection equipment - Power frequency immunity tests

Specifies general requirements for power frequency immunity tests for measuring relays and protection equipment for power system protection, including the control, monitoring and process interface equipment used with those systems. The objective of the tests is to confirm that the equipment under test will operate correctly when energised and subjected to short duration, conducted, common and differential mode power frequency disturbances. Is based on IEC 61000-4-16.
Standard replaced by (1)
International standard Cancelled
Measuring relays and protection equipment - Part 26: Electromagnetic compatibility requirements

IEC 60255-26:2013 is applicable to measuring relays and protection equipment, taking into account combinations of devices to form schemes for power system protection including the control, monitoring, communication and process interface equipment used with those systems. This standard specifies the requirements for electromagnetic compatibility for measuring relays and protection equipment. The requirements specified in this standard are applicable to measuring relays and protection equipment in a new condition and all tests specified are type tests only. This new edition includes the following significant technical changes with respect to the previous edition: - definition of test specifications, test procedures and acceptance criteria per phenomena and port under test in one document; - extension of radiated emission measurement for frequencies above 1 GHz; - limitation of radiated emission measurement at 3 m distance for small equipment only; - addition of zone A and zone B test level on surge test; - extension of tests on the auxiliary power supply port by a.c. and d.c. voltage dips, a.c. component in d.c. (ripple) and gradual shut-down/start-up; - harmonization of acceptance criteria for immunity tests.