IEC 60287:1982

IEC 60287:1982

January 1982
International standard Cancelled

Calculation of the continuous current rating of cables (100% load factor)

Deals solely with the condition of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, troughs or in steel pipes, as well as cables in air. The term Note: - Appendix A Reference ambient temperatures, and thermal resistivities of soils in various countries. Appendix B Information required from the purchaser for the selection of the appropriate type of cable. Appendix C Digital calculation of quantities given graphically.

Main informations

Collections

International IEC standards

Publication date

January 1982

Number of pages

127 p.

Reference

IEC 60287:1982

Print number

2
Sumary
Calculation of the continuous current rating of cables (100% load factor)

Deals solely with the condition of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, troughs or in steel pipes, as well as cables in air. The term Note: - Appendix A Reference ambient temperatures, and thermal resistivities of soils in various countries. Appendix B Information required from the purchaser for the selection of the appropriate type of cable. Appendix C Digital calculation of quantities given graphically.
Standard replaced by (3)
IEC 60287-3-1:1995
August 1995
International standard Cancelled
Electric cables - Calculation of the current rating - Part 3: Sections on operating conditions - Section 1: Reference operating conditions and selection of cable type

Is applicable to the conditions of steady-state operation of cables at all alternating voltages, and direct voltages up to 5 kV, buried directly in the ground, in ducts, troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air. This section concerns reference operatings and selection of cable type.

IEC 60287-2-1:1994
December 1994
International standard Cancelled
Electric cables - Calculation of the current rating - Part 2: Thermal resistance - Section 1: Calculation of thermal resistance

Is solely applicable to the conditions of steady-state operation of cables at all alternating voltages, as well as in direct voltages up to 5 kV, buried directly in the ground, in ducts , in troughs or in steel pipes, both with and without partial drying-out of the soil, as well as cables in air.

International standard Cancelled
Corrigendum 1 - Electric cables - Calculation of the current rating - Part 1-1: Current rating equations (100 % load factor) and calculation of losses - General

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ