IEC 60317-27:2013

IEC 60317-27:2013

October 2013
International standard Cancelled

Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire

IEC 60317-27:2013 specifies the requirements of paper tape covered rectangular copper winding wires. This covering consists of two or more layers of paper tape, all in the same direction and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this standard is:- width: min. 2,0 mm max. 16,0 mm;- thickness: min. 0,80 mm max. 5,60 mm. The paper tapes covered by this standard are restricted to those specified in IEC 60554-1 having thicknesses in the range 25 ?m to 125 ?m inclusive. This fourth edition cancels and replaces the third edition published in 1998, Amendment 1:1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- new subclause containing general notes on winding wire, formerly a part of the scope;- revision to references to IEC 60317-0-2:2013 to clarify that their application is normative;- new 3.3, Appearance;- modification to 4.4, Increase in dimensions due to paper tape covering;- deletion of Clause 22, High temperature failure;- new Clause 23, Pin hole test. Keywords: requirements of paper tape covered rectangular copper winding wires, winding coils for oil immersed transformersThis publication is to be read in conjunction with IEC 60317-0-2:2013.

Main informations

Collections

International IEC standards

Publication date

October 2013

Number of pages

24 p.

Reference

IEC 60317-27:2013
Sumary
Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire

IEC 60317-27:2013 specifies the requirements of paper tape covered rectangular copper winding wires. This covering consists of two or more layers of paper tape, all in the same direction and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this standard is:
- width: min. 2,0 mm max. 16,0 mm;
- thickness: min. 0,80 mm max. 5,60 mm. The paper tapes covered by this standard are restricted to those specified in IEC 60554-1 having thicknesses in the range 25 ?m to 125 ?m inclusive. This fourth edition cancels and replaces the third edition published in 1998, Amendment 1:1999. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- new subclause containing general notes on winding wire, formerly a part of the scope;
- revision to references to IEC 60317-0-2:2013 to clarify that their application is normative;
- new 3.3, Appearance;
- modification to 4.4, Increase in dimensions due to paper tape covering;
- deletion of Clause 22, High temperature failure;
- new Clause 23, Pin hole test. Keywords: requirements of paper tape covered rectangular copper winding wires, winding coils for oil immersed transformers

This publication is to be read in conjunction with IEC 60317-0-2:2013.
Replaced standards (4)
International standard Cancelled
Corrigendum 1 - Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire

IEC 60317-27:1998
January 1998
International standard Cancelled
Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire

The contents of the corrigendum of April 2002 have been included in this copy.

International standard Cancelled
Corrigendum 1 to Amendment 1 - Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire

International standard Cancelled
Amendment 1 - Specifications for particular types of winding wires - Part 27: Paper tape covered rectangular copper wire

The contents of the corrigendum of April 2002 have been included in this copy.

See more
Standard replaced by (1)
IEC 60317-27-3:2019
November 2019
International standard Current
Specifications for particular types of winding wires - Part 27-3: Paper tape covered rectangular copper wire

IEC 60317-27-3:2019 specifies the requirements of paper tape covered rectangular copper winding wires. This covering consists of two or more layers of paper tape and is primarily intended for winding coils for oil immersed transformers. The range of nominal conductor dimensions covered by this document is - width: min. 2,0 mm max. 31,5 mm; - thickness: min. 0,80 mm max. 10,0 mm. The paper tapes included in this document are restricted to those specified in IEC 60554-1 and IEC 60554-3-5. Keywords: paper tape covered rectangular copper winding wires