IEC 60318-3:2014

IEC 60318-3:2014

December 2014
International standard Current

Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry

IEC 60318-3:2014 specifies an acoustic coupler for the measurement of supra-aural audiometric earphones in the frequency range from 125 Hz to 8 000 Hz. The sound pressure developed by an earphone is not, in general, the same in the coupler as in a person's ear. However, the acoustic coupler can be used as an objective and reproducible means of measuring the output of supra-aural earphones. It can be used for specifying reference equivalent threshold sound pressure levels for the calibration of audiometers. This second edition cancels and replaces the first edition published in 1998 and constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:- adjustment of terms and wording to the other parts of IEC 60318;- introduction of maximum permitted uncertainties;- and revised requirements for static pressure equalization. Keywords: electroacoustics, deafness, hearing aids

Main informations

Collections

International IEC standards

Publication date

December 2014

Number of pages

24 p.

Reference

IEC 60318-3:2014
Sumary
Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry

IEC 60318-3:2014 specifies an acoustic coupler for the measurement of supra-aural audiometric earphones in the frequency range from 125 Hz to 8 000 Hz. The sound pressure developed by an earphone is not, in general, the same in the coupler as in a person's ear. However, the acoustic coupler can be used as an objective and reproducible means of measuring the output of supra-aural earphones. It can be used for specifying reference equivalent threshold sound pressure levels for the calibration of audiometers. This second edition cancels and replaces the first edition published in 1998 and constitutes a technical revision which includes the following significant technical changes with respect to the previous edition:
- adjustment of terms and wording to the other parts of IEC 60318;
- introduction of maximum permitted uncertainties;
- and revised requirements for static pressure equalization. Keywords: electroacoustics, deafness, hearing aids
Replaced standards (1)
IEC 60318-3:1998
August 1998
International standard Cancelled
Electroacoustics - Simulators of human head and ear - Part 3: Acoustic coupler for the calibration of supra-aural earphones used in audiometry

Describes an acoustic coupler for loading supra-aural audiometric earphones as specified in ISO 389 with a specified acoustic impedance, when calibrating audiometers, in the frequency range of 125 Hz to 8 000 Hz. Cancels and replaces IEC 60303 (1970).