IEC 60364-5-54:2011

IEC 60364-5-54:2011

March 2011
International standard Current

Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors

IEC 60364-5-54:2011 addresses the earthing arrangements and protective conductors including protective bonding conductors in order to satisfy the safety of the electrical installation. This third edition cancels and replaces the second edition, published in 2002, and constitutes a technical revision. The main changes with respect to the previous edition are listed below:- clarification of the definition of protective conductor;- improved specification of mechanical characteristics of the earth electrode;- introduction of earth electrode for protection against electric shock and lighting protection;- annexes describing concrete-embedded foundation earth electrodes and soil-embedded earth electrode.

Main informations

Collections

International IEC standards

Publication date

March 2011

Number of pages

83 p.

Reference

IEC 60364-5-54:2011
Sumary
Low-voltage electrical installations - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements and protective conductors

IEC 60364-5-54:2011 addresses the earthing arrangements and protective conductors including protective bonding conductors in order to satisfy the safety of the electrical installation. This third edition cancels and replaces the second edition, published in 2002, and constitutes a technical revision. The main changes with respect to the previous edition are listed below:
- clarification of the definition of protective conductor;
- improved specification of mechanical characteristics of the earth electrode;
- introduction of earth electrode for protection against electric shock and lighting protection;
- annexes describing concrete-embedded foundation earth electrodes and soil-embedded earth electrode.
Replaced standards (1)
International standard Cancelled
Electrical installations of buildings - Part 5-54: Selection and erection of electrical equipment - Earthing arrangements, protective conductors and protective bonding conductors

Addresses the earthing arrangements, protective conductors and protective bonding conductors in order to satisfy the safety of the electrical installation. Has the status of a basic safety publication in accordance with IEC Guide 104.