Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services

IEC 60364-5-56:2009 covers general requirements for safety services, selection and erection of electrical supply systems for safety services and electrical safety sources. Standby electrical supply systems are outside the scope of this part. This part does not apply to installations in hazardous areas (BE3), for which requirements are given in IEC 60079-14. This second edition of IEC 60364-5-56 comes about as a result of changes to Clause 556, Safety services, of IEC 60364-5-55 (2001), as modified by its amendment 1 (2001). It replaces Clause 556 of IEC 60364-5-55:2001. Clause 556 is to be withdrawn at the time of publication of this new Part 56. The main changes with regard to the previous edition are listed below:1) Many more definitions are included, e.g. response time, central power supply system, low power supply system, preferential circuit and escape route.2) Automatic supplies are now classified according to the maximum changeover times, for example a supply classified as short break means an automatic supply is available within 0,5 s.3) Safety sources that can operate in parallel are specifically recognized in 560.6.9.4) Requirements are now given for batteries used for safety sources for central and low power supply sources.5) Drawings are now required, such as a single-line diagram, drawings showing the location of equipment and a list of equipment permanently connected to the safety power supply.6) Operating instructions are now required.7) Detailed requirements are now given for emergency escape lighting applications, direct current circuits and fire protection applications.8) Additional requirements for initial verification and periodic inspection and testing are now included in the standard.9) Two annexes are now included (Annex A and Annex B) giving guidance for emergency lighting and guidance for fire protection equipment, respectively.

Main informations

Collections

International IEC standards

Publication date

July 2009

Number of pages

38 p.

Reference

IEC 60364-5-56:2009
Sumary
Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services

IEC 60364-5-56:2009 covers general requirements for safety services, selection and erection of electrical supply systems for safety services and electrical safety sources. Standby electrical supply systems are outside the scope of this part. This part does not apply to installations in hazardous areas (BE3), for which requirements are given in IEC 60079-14. This second edition of IEC 60364-5-56 comes about as a result of changes to Clause 556, Safety services, of IEC 60364-5-55 (2001), as modified by its amendment 1 (2001). It replaces Clause 556 of IEC 60364-5-55:2001. Clause 556 is to be withdrawn at the time of publication of this new Part 56. The main changes with regard to the previous edition are listed below:
1) Many more definitions are included, e.g. response time, central power supply system, low power supply system, preferential circuit and escape route.
2) Automatic supplies are now classified according to the maximum changeover times, for example a supply classified as short break means an automatic supply is available within 0,5 s.
3) Safety sources that can operate in parallel are specifically recognized in 560.6.9.
4) Requirements are now given for batteries used for safety sources for central and low power supply sources.
5) Drawings are now required, such as a single-line diagram, drawings showing the location of equipment and a list of equipment permanently connected to the safety power supply.
6) Operating instructions are now required.
7) Detailed requirements are now given for emergency escape lighting applications, direct current circuits and fire protection applications.
8) Additional requirements for initial verification and periodic inspection and testing are now included in the standard.
9) Two annexes are now included (Annex A and Annex B) giving guidance for emergency lighting and guidance for fire protection equipment, respectively.
Replaced standards (2)
IEC 60364-5-56:1980
January 1980
International standard Cancelled
Electrical installations of buildings. Part 5: Selection and erection of electrical equipment. Chapter 56: Safety services

Gives specifications concerning the sources of current, the circuits and the equipment used.

International standard Cancelled
Amendment 1 - Electrical installations of buildings. Part 5: Selection and erection of electrical equipment. Chapter 56: Safety services

Standard replaced by (1)
IEC 60364-5-56:2018
November 2018
International standard Current
Low-voltage electrical installations - Part 5-56: Selection and erection of electrical equipment - Safety services

IEC 60364-5-56:2018 covers general requirements for safety services, selection and erection of electrical supply systems for safety services and electrical safety sources. Standby electrical supply systems are outside the scope of this part. This part does not apply to installations in hazardous areas (BE3), for which requirements are given in IEC 60079-14. This third edition cancels and replaces the second edition published in 2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: 1) Modifications to normative references and terms and definitions. 2) Under electrical circuits for safety services, addition of requirements concerning circuit and overcurrent protection in order to maintain reliability of safety service power supplies under fire conditions. 3) Under electrical circuits for safety services, addition of requirements stating that circuits for safety services are not to be protected by RCDs or AFDDs. 4) Under emergency lighting applications, addition of requirements to prevent emergency lighting systems being adversely affected by any control system. 5) Addition of requirements for all emergency luminaires in the area to provide full design light output in the event of any final circuit failure. 6) Addition of a new Annex D (informative): Fire switch. 7) Addition of a new Annex E (informative): Example of installation methods of safety services with cable management system. 8) Addition of a new Annex F (informative): Wiring systems. 9) Addition of a new Annex G (informative): Guidance on suitable locations for electrical sources for safety services.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ