IEC 60364-6-61:2001

IEC 60364-6-61:2001

August 2001
International standard Cancelled

Electrical installations of buildings - Part 6-61: Verification - Initial verification

Lays down requirements for the verification, by inspection and testing, of the compliance of the installation with the relevant requirements of other parts of IEC 60364. Criteria for testing are given and tests described.This part is concerned only with new installations; it is not concerned with the inspection and testing of existing installations. However, the criteria for inspection and the tests described may be applied, if thought appropriate, to existing installations.

Main informations

Collections

International IEC standards

Publication date

August 2001

Number of pages

57 p.

Reference

IEC 60364-6-61:2001

Print number

2
Sumary
Electrical installations of buildings - Part 6-61: Verification - Initial verification

Lays down requirements for the verification, by inspection and testing, of the compliance of the installation with the relevant requirements of other parts of IEC 60364. Criteria for testing are given and tests described. This part is concerned only with new installations; it is not concerned with the inspection and testing of existing installations. However, the criteria for inspection and the tests described may be applied, if thought appropriate, to existing installations.
Replaced standards (2)
International standard Cancelled
Amendment 1 - Electrical installations of buildings. Part 6: Verification. Chapter 61: Initial verification

International standard Cancelled
Amendment 2 - Electrical installations of buildings. Part 6: Verification. Chapter 61: Initial verification

Standard replaced by (1)
IEC 60364-6:2006
February 2006
International standard Cancelled
Low-voltage electrical installations - Part 6: Verification

Provides requirements for initial verification, by inspection and testing, of an electrical installation to determine, as far as reasonably practicable, whether the requirements of the other parts of IEC 60364 have been met and requirements for the reporting of the results of the initial verification. The initial verification takes place upon completion of a new installation or completion of additions or of alterations to existing installations. Provides requirements for periodic verification of an electrical installation to determine, as far as reasonably practicable, whether the installation and all its constituent equipment are in a satisfactory condition for use and requirements for the reporting of the results of the periodic verification.