IEC 60364-7-710:2021
Low-voltage electrical installations - Part 7-710: Requirements for special installations or locations - Medical locations
IEC 60364-7-710:2021 applies to electrical installations in medical locations so as to provide safety of patients and medical staff. These requirements refer to:? hospitals and clinics or equivalent institutions (including equivalent transportable and mobile locations);which, subject to assessment (710.30), can also include:? sanatoriums and health clinics;? dedicated locations in homes for senior citizens and aged care homes, where patients receive medical care;? medical centres, outpatients' clinics and departments, casualty wards;? other outpatients' institutions (industrial, sports and others);? medical and dental practices;? dedicated medical rooms in the workplace;? other locations where medical electrical equipment is used;? veterinary clinics;? rooms in existing installations where a change of utilization for medical applications occur.This list is not exhaustive.The requirements of this document do not apply to ME equipment or ME systems.This edition includes the following significant technical changes with respect to the previous edition:a) the scope provides improved information to the application of this document;b) some terms and definitions have been revised;c) the validity of the respective parts of the IEC 60364 series has been verified and clauses updated;d) Clause 710.30 has been extended;e) Clause 710.41 has been updated;f) Clause 710.413 has been renumbered as Clause 710.411;g) in 710.411 insulation fault location systems have been added;h) Clause 710.421 has been extended to include arc fault detection devices;i) Clause 710.44 has been added;j) Clause 710.51 has been updated and now covers distribution boards and electrical operating areas;k) Clause 710.514, has been extended and includes separate subclauses on diagrams, documentation and operating instructions;l) Subclauses 710.531 to 710.537 have been added;m) Clause 710.55 has been updated;n) Clause 710.56 has been added;o) Clause 710.6, Verification, has been revised;p) Annex A was deleted, and the contents integrated into 710.560.4;q) former Annex B is now Annex A and has been updated;r) an informative Annex B on guidance concerning electromagnetic interferences (EMI) in installations of buildings has been added
IEC 60364-7-710:2021 applies to electrical installations in medical locations so as to provide safety of patients and medical staff. These requirements refer to:
? hospitals and clinics or equivalent institutions (including equivalent transportable and mobile locations);
which, subject to assessment (710.30), can also include:
? sanatoriums and health clinics;
? dedicated locations in homes for senior citizens and aged care homes, where patients receive medical care;
? medical centres, outpatients' clinics and departments, casualty wards;
? other outpatients' institutions (industrial, sports and others);
? medical and dental practices;
? dedicated medical rooms in the workplace;
? other locations where medical electrical equipment is used;
? veterinary clinics;
? rooms in existing installations where a change of utilization for medical applications occur.
This list is not exhaustive.
The requirements of this document do not apply to ME equipment or ME systems.
This edition includes the following significant technical changes with respect to the previous edition:
a) the scope provides improved information to the application of this document;
b) some terms and definitions have been revised;
c) the validity of the respective parts of the IEC 60364 series has been verified and clauses updated;
d) Clause 710.30 has been extended;
e) Clause 710.41 has been updated;
f) Clause 710.413 has been renumbered as Clause 710.411;
g) in 710.411 insulation fault location systems have been added;
h) Clause 710.421 has been extended to include arc fault detection devices;
i) Clause 710.44 has been added;
j) Clause 710.51 has been updated and now covers distribution boards and electrical operating areas;
k) Clause 710.514, has been extended and includes separate subclauses on diagrams, documentation and operating instructions;
l) Subclauses 710.531 to 710.537 have been added;
m) Clause 710.55 has been updated;
n) Clause 710.56 has been added;
o) Clause 710.6, Verification, has been revised;
p) Annex A was deleted, and the contents integrated into 710.560.4;
q) former Annex B is now Annex A and has been updated;
r) an informative Annex B on guidance concerning electromagnetic interferences (EMI) in installations of buildings has been added
Applies to electrical installations in medical locations so as to ensure safety of patients and medical staff. These requirements, in the main, refer to hospitals, private clinics, medical and dental practices, health care centres and dedicated medical rooms in the work place.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ