IEC 60364-7-713:1996

IEC 60364-7-713:1996

February 1996
International standard Cancelled

Electrical installations of buildings - Part 7: Requirements for special installations and locations - Section 713: Furniture

Applies to furniture connected by fixed wiring to the electricalinstallation of the building and also to the prefabricatedfurniture and furniture connected by means of a plug andsocket-outlet unless these items are the subject of other IECpublications. Electrical equipment of furniture shall be connectedto a single-phase supply < or = 240V, and the total load currentshall not exceed 16 A.

Main informations

Collections

International IEC standards

Publication date

February 1996

Number of pages

13 p.

Reference

IEC 60364-7-713:1996

Print number

1 - 13/06/2005
Sumary
Electrical installations of buildings - Part 7: Requirements for special installations and locations - Section 713: Furniture

Applies to furniture connected by fixed wiring to the electrical installation of the building and also to the prefabricated furniture and furniture connected by means of a plug and socket-outlet unless these items are the subject of other IEC publications. Electrical equipment of furniture shall be connected to a single-phase supply < or = 240V, and the total load current shall not exceed 16 A.
Standard replaced by (1)
IEC 60364-7-713:2013
February 2013
International standard Current
Low-voltage electrical installations - Part 7-713: Requirements for special installations or locations - Furniture

IEC 60364-7-713:2013 applies to the wiring system of furniture (and similar fitments) which is connected to the electrical installation. Examples are beds, cupboards, desks and shop display cases, in which electrical equipment such as luminaires, installation couplers according to IEC 61535, socket-outlets, switching devices and wiring systems are installed. This second edition cancels and replaces the first edition, published in 1996, and constitutes a technical revision. This edition includes changes to the scope: the requirements of Part 7-713 now apply to electrical equipment of furniture connected to a supply with a nominal voltage UO not exceeding 230 V and a total load current not exceeding 32 A, including three-phase 32 A supplies. This new edition makes reference to Part 4-41 additional protection and requires that the fixed circuit is protected by an RCD with a rated residual operating current not exceeding 30 mA.