IEC 60384-22:2019

IEC 60384-22:2019

January 2019
International standard Cancelled

Fixed capacitors for use in electronic equipment - Part 22: Sectional specification - Fixed surface mount multilayer capacitors of ceramic dielectric, Class 2

IEC 60384-22:2019 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 2, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance levels, lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: - revision of the structure in accordance with ISO/IEC Directives, Part 2:2016 (seventh edition) to the extent practicable, and for harmonizing with IEC 60384-21;- deletion of the description on the permissible reactive power in 6.2.2 because it is not appropriate for the purposes of this document;- the dimensions of 0201M in Annex A have been added.

Main informations

Collections

International IEC standards

Publication date

January 2019

Number of pages

92 p.

Reference

IEC 60384-22:2019
Sumary
Fixed capacitors for use in electronic equipment - Part 22: Sectional specification - Fixed surface mount multilayer capacitors of ceramic dielectric, Class 2

IEC 60384-22:2019 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 2, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this document is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification are of equal or higher performance levels, lower performance levels are not permitted. This edition includes the following significant technical changes with respect to the previous edition: - revision of the structure in accordance with ISO/IEC Directives, Part 2:2016 (seventh edition) to the extent practicable, and for harmonizing with IEC 60384-21;
- deletion of the description on the permissible reactive power in 6.2.2 because it is not appropriate for the purposes of this document;
- the dimensions of 0201M in Annex A have been added.
Replaced standards (1)
IEC 60384-22:2011
December 2011
International standard Cancelled
Fixed capacitors for use in electronic equipment - Part 22: Sectional specification - Fixed surface mount multilayer capacitors of ceramic dielectric, Class 2

IEC 60384-22:2011 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 2, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included, but are covered by IEC 60384-14. The object of this standard is to prescribe preferred ratings and characteristics and to select from IEC 60384-1 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements prescribed in detail specifications referring to this sectional specification should be of equal or higher performance level, lower performance levels are not permitted. This second edition cancels and replaces the first edition published in 2004 and contains the following significant technical changes with respect to the previous edition. - The measuring frequency of 1 MHz has been reduced to 1 kHz for 100 pF, see 4.5.1 Capacitance. - The test voltage of 1,2 UR at UR greater or equal to 1 000 V has been added in 4.5.4 Voltage proof. - Detail test conditions have been added in 4.7 Shear test and 4.8 Substrate bending test. - Test conditions applying lead free solder alloy (Sn-Ag-Cu) have been included in 4.9 Resistance to soldering heat and 4.10 Solderability. - A selection of the test conditions according to marketing needs has been stated in 4.13 Damp heat, steady state. - The dimensions of 0402 M in Annex A have been added. - The temperature characteristics code of capacitance for the reference temperature of 25 °C has been added, see Annex C.

Standard replaced by (1)
IEC 60384-22:2024
June 2024
International standard Current
Fixed capacitors for use in electronic equipment - Part 22: Sectional specification - Fixed surface mount multilayer capacitors of ceramic dielectric, Class 2

IEC 60384-22:2024 is applicable to fixed unencapsulated surface mount multilayer capacitors of ceramic dielectric, Class 2, for use in electronic equipment. These capacitors have metallized connecting pads or soldering strips and are intended to be mounted on printed boards, or directly onto substrates for hybrid circuits. Capacitors for electromagnetic interference suppression are not included but are covered by IEC 60384-14. The object of this document is to specify preferred ratings and characteristics and to select from IEC 60384-1:2021 the appropriate quality assessment procedures, tests and measuring methods and to give general performance requirements for this type of capacitor. Test severities and requirements specified in detail specifications referring to this sectional specification provide specific test severities and requirements of an equal or higher performance level. Further information on the conception of generic, sectional and detail specifications can be found in the Introduction of IEC 60384-1:2021. This edition includes the following significant technical changes with respect to the previous edition: a) The document has been completely restructured to comply with the ISO/IEC Directives, Part 2 and to make it more useable; tables, figures and references have been revised accordingly. b) The requirements of reference temperature 25 °C has been added in Table 5, Table 9, Table 10, Table 12, Table 14 and Table 17. c) The table of temperature characteristics of capacitance for the reference temperature 25 °C have been added in Table C.1, Table C.2 and Table C.3. d) The requirement in 5.5.2 (visual examination) has been repeated in 5.9.3, 5.10.6, 5.11.4, 5.12.6, 5.13.8, 5.14.6 and 5.15.6. e) The deflection D in the very robust designs has been added in 5.9.1. f) Annex C has been changed informative into normative. g) Clause D.5 (Test schedule for quality conformance inspection) has been newly added to withdraw the blank detail specification: IEC 60384-22-1.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ