IEC 60404-7:2019

IEC 60404-7:2019

January 2019
International standard Current

Magnetic materials - Part 7: Method of measurement of the coercivity (up to 160 kA/m) of magnetic materials in an open magnetic circuit

IEC 60404-7:2019 specifies a method of measurement of the coercivity of magnetic materials in an open magnetic circuit. This document is applicable to all magnetic materials with coercivities from 0,2 A/m to 160 kA/m.This edition includes the following significant technical changes with respect to the previous edition:Clause 1: The scope includes a more detailed description of the magnetic materials which applies to this standard;Clause 4: Figure 2 ? circuit diagram for methods A and B was simplified and the fluxgate probes inside the solenoid have been added;Clause 7: Compensation for the earth?s magnetic field and for static and dynamic magnetic noise fields has been added;Clause 8: Magnetic shielding of the measuring region has been added;9.2.2: The measuring methods for local and integral measurement of the flux in the test specimen have been separated and the limitations in size and shape of the test specimen have been considered.9:3: The method C with a VSM (Vibrating Sample Magnetometer) has been moved from 9.3 to the Annex B.The term "complex shaped test specimen" has been replaced in several clauses by "test specimen different from ellipsoids".The character of Annex A has been changed from ?informative? to ?normative?.

Main informations

Collections

International IEC standards

Publication date

January 2019

Number of pages

34 p.

Reference

IEC 60404-7:2019
Sumary
Magnetic materials - Part 7: Method of measurement of the coercivity (up to 160 kA/m) of magnetic materials in an open magnetic circuit

IEC 60404-7:2019 specifies a method of measurement of the coercivity of magnetic materials in an open magnetic circuit. This document is applicable to all magnetic materials with coercivities from 0,2 A/m to 160 kA/m.
This edition includes the following significant technical changes with respect to the previous edition:
Clause 1: The scope includes a more detailed description of the magnetic materials which applies to this standard;
Clause 4: Figure 2 ? circuit diagram for methods A and B was simplified and the fluxgate probes inside the solenoid have been added;
Clause 7: Compensation for the earth?s magnetic field and for static and dynamic magnetic noise fields has been added;
Clause 8: Magnetic shielding of the measuring region has been added;
9.2.2: The measuring methods for local and integral measurement of the flux in the test specimen have been separated and the limitations in size and shape of the test specimen have been considered.
9:3: The method C with a VSM (Vibrating Sample Magnetometer) has been moved from 9.3 to the Annex B.
The term "complex shaped test specimen" has been replaced in several clauses by "test specimen different from ellipsoids".
The character of Annex A has been changed from ?informative? to ?normative?.
Replaced standards (1)
IEC 60404-7:1982
January 1982
International standard Cancelled
Magnetic materials. Part 7: Method of measurement of the coercivity of magnetic materials in an open magnetic circuit

Applies to magnetic materials having a coercivity up to 500 kA/m. Specifies the method of measurement of the coercivity of magnetic materials in an open circuit.