IEC 60507:1991

IEC 60507:1991

April 1991
International standard Cancelled

Artificial pollution tests on high-voltage insulators to be used on a.c. systems

Is applicable for the determination of the power frequencywithstand characteristics of ceramic and glass insulators to beused outdoors and exposed to polluted atmospheres, on a.c. systemswith the highest voltage of the system ranging from 1 000 V up to765 kV.These tests are not directly applicable to greased insulators or tospecial types of insulators (insulators with conductive glaze orcovered with any organic insulating material).

Main informations

Collections

International IEC standards

Publication date

April 1991

Number of pages

56 p.

Reference

IEC 60507:1991

Print number

2 - 13/06/2005
Sumary
Artificial pollution tests on high-voltage insulators to be used on a.c. systems

Is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system ranging from 1 000 V up to 765 kV. These tests are not directly applicable to greased insulators or to special types of insulators (insulators with conductive glaze or covered with any organic insulating material).
Standard replaced by (1)
IEC 60507:2013
December 2013
International standard Current
Artificial pollution tests on high-voltage ceramic and glass insulators to be used on a.c. systems

IEC 60507:2013 is applicable for the determination of the power frequency withstand characteristics of ceramic and glass insulators to be used outdoors and exposed to polluted atmospheres, on a.c. systems with the highest voltage of the system greater than 1 000 V. These tests are not directly applicable to polymeric insulators, to greased insulators or to special types of insulators (insulators with semiconducting glaze or covered with any organic insulating material). The object of this International Standard is to prescribe procedures for artificial pollution tests applicable to insulators for overhead lines, substations and traction lines and to bushings. It may also be applied to hollow insulators with suitable precautions to avoid internal flashover. In applying these procedures to apparatus incorporating hollow insulators, the relevant technical committees should consider their effect on any internal equipment and the special precautions which may be necessary. This edition includes the following significant technical changes with respect to the previous edition: a) Corrections and the addition of explanatory material; b) The addition of Clause 4.3.2 on atmospheric correction; c) The change of the upper limit of conductivity of water to 0.1 S/m; and d) The extension to UHV voltages. The contents of the corrigendum of August 2018 have been included in this copy.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ