IEC 60598-1:2003
Luminaires - Part 1: General requirements and tests
This Part 1 of International Standard IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction and electrical construction.
This Part 1 of International Standard IEC 60598 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction and electrical construction.
Covers general requirements for the classification and marking of luminaires and for their mechanical and electrical construction, together with related tests. Is applicable to luminaires for use with tungsten filaments, tubular fluorescent and other discharge lamps on supply voltages not exceeding 1 000 V. This publication supersedes IEC 60162 (1972). The contents of the interpretation sheet of March 2001 and September 2001 have been included in this copy.
IEC 60598-1:2008 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction and electrical construction. This seventh edition cancels and replaces the sixth edition published in 2003. It constitutes a technical revision. The major changes which may affect certification are given in Annex R. Annex R shows where a new text has been included which contains more serious/critical requirements requiring products to be re-tested. Subclauses 1.2.71, 3.2.19, 4.21, 4.24, Annex P: Requirements self shielded lamps and UV protection. Subclauses 1.2.42, 5.2.14, 5.2.16, 8.2.3, 9.2: SELV requirements. Subclauses 1.2.78, 1.2.79, 1.2.80, 3.3, 10.1, 10.3, Annex G: Touch current, protective current and electric burn. Subclauses 1.2.81, 1.2.82, 3.2.20, 4.14.3, Table 12.1: Hot surfaces. Subclauses 0.5.2, 1.2.83, Annex V: Terminal block with integrated earthing contact. Subclauses 3.2.22, Figure 1: replaceable fuses. Subclauses 1.2.8, 8.2.1, 8.2.4, 8.2.5, 8.2.6: Access to basic insulation of luminaries. Subclauses 2.4, 12.6, 3.2.9, 3.2.21, 4.16, Annex D, Annex N: Marking of luminaires not suitable for mounting on normally flammable surfaces and covering with insulation. Subclause 4.12.4: Torque requirements for lampholders with a single means of fixing exposed to a rotary action. Subclause 9.2: Requirements for protection of lamp splashing. The contents of the corrigenda of October 2011 and December 2011 have been included in this copy.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ