IEC 60598-1:2020
IEC 60598-1:2020

IEC 60598-1:2020

August 2020
International standard Cancelled

Luminaires - Part 1: General requirements and tests

IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;- Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;- Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;- Addition of Subclause 3.3.25, UV protection of cable;- Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);- Revision of the requirements for functional earth and protective earth;- Addition of Clause 4.35, Protection against fast rotating parts;- Revision of Clause 3.2, Rated voltage marking;- Revision of Subclause 5.2.10, Cord anchorage;- Revision of Annex G for touch current and protective conductor current test set-up;- Addition of requirements for constant light output function and programmable current output;- Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;- Introduction of PELV;- Introduction of Ethernet power supply connection for luminaires (PoE);- Section 9, Introduction of IPX9;- Addition of Subclause 3.3.26 for wall mounted luminaires;- Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;- Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;- Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;- Revision of Subclause 10.2.2, alternative DC electric strength test;- Revision of Annex D for recessed luminaires;- Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;- Revision of use of bridging capacitors in luminaires;- Revision of electrical connection to class III plugs.The contents of the Interpretation sheet 1 (2023-08) have been included in this copy.

Main informations

Collections

International IEC standards

Publication date

August 2020

Number of pages

229 p.

Reference

IEC 60598-1:2020

ICS Codes

29.140.40   Luminaires

Print number

1
Sumary
Luminaires - Part 1: General requirements and tests

IEC 60598-1:2020 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this document cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This ninth edition cancels and replaces the eighth edition published in 2014 and Amendment 1:2017. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Revision of Clause 4.30, Fixing cover live parts of non-user replaceable light source;
- Subclause 4.24.2, Blue Light Hazard: removal of Risk Group 0;
- Subclause 5.2.16: additional requirements for AC mains appliance inlets related to IEC 61984;
- Addition of Subclause 3.3.25, UV protection of cable;
- Addition of Clause 4.34, Inclusion of EMF safety requirements (IEC 62493);
- Revision of the requirements for functional earth and protective earth;
- Addition of Clause 4.35, Protection against fast rotating parts;
- Revision of Clause 3.2, Rated voltage marking;
- Revision of Subclause 5.2.10, Cord anchorage;
- Revision of Annex G for touch current and protective conductor current test set-up;
- Addition of requirements for constant light output function and programmable current output;
- Revision of Subclause 8.2.3 c), touch voltage limits for interrupted DC voltage;
- Introduction of PELV;
- Introduction of Ethernet power supply connection for luminaires (PoE);
- Section 9, Introduction of IPX9;
- Addition of Subclause 3.3.26 for wall mounted luminaires;
- Revision of Annex D introducing alternative thermal tests for luminaires with ta marking higher than 25°C;
- Revision of Table 10.3 and Subclause 3.3.19 for protective conductor current limits;
- Track-mounted luminaires: cross reference to Annex A of IEC 60570:2003/AMD2:2019;
- Revision of Subclause 10.2.2, alternative DC electric strength test;
- Revision of Annex D for recessed luminaires;
- Subclause 4.12.5: revision of Table 4.2 for torque test on metal glands;
- Revision of use of bridging capacitors in luminaires;
- Revision of electrical connection to class III plugs.
The contents of the Interpretation sheet 1 (2023-08) have been included in this copy.
Replaced standards (6)
IEC 60598-1:2014/COR3:2017
International standard Cancelled
Corrigendum 3 - Luminaires - Part 1: General requirements and tests

 

IEC 60598-1:2014/AMD1:2017
International standard Cancelled
Amendment 1 - Luminaires - Part 1: General requirements and tests

IEC 60598-1:2014
IEC 60598-1:2014
May 2014
International standard Cancelled
Luminaires - Part 1: General requirements and tests

IEC 60598-1:2014 specifies general requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. The requirements and related tests of this standard cover: classification, marking, mechanical construction, electrical construction and photobiological safety. This eighth edition cancels and replaces the seventh edition published in 2008. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition: a) requirements to support the construction methods for new LED luminaires entering the market; b) photobiological requirements extended; c) more precise requirements for insulation between different types of electrical circuit; d) other general updates and improvements. The contents of the corrigenda of October 2015, of December 2015, of May 2017 and interpretation sheet 1 of May 2016 have been included in this copy.

IEC 60598-1:2014/COR1:2015
International standard Cancelled
Corrigendum 1 - Luminaires - Part 1: General requirements and tests

IEC 60598-1:2014/COR2:2015
International standard Cancelled
Corrigendum 2 - Luminaires - Part 1: General requirements and tests

IEC 60598-1:2014/ISH1:2016
International standard Cancelled
Interpretation sheet 1 - Luminaires - Part 1: General requirements and tests

See more
Standard replaced by (1)
IEC 60598-1:2024
IEC 60598-1:2024
November 2024
International standard Current
Luminaires - Part 1: General requirements and tests

IEC 60598-1:2024 specifies general safety requirements for luminaires, incorporating electric light sources for operation from supply voltages up to 1 000 V. Requirements for semi-luminaires are included in this document. This tenth edition cancels and replaces the ninth edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) new structure to comply with the ISO/IEC Directives, Part 2; b) addition of a new Annex V for comparison with the previous edition; c) revision of 7.32 for SPDs and for SPCs; d) the terms "live part" and "active part" were reviewed and aligned with the definitions of "live part" and "hazardous live part" given in IEC 60050-195; e) revision of 7.14.2 for conductor mechanical stress; f) revision of 14.5.2, Item 4 to include controlgear; g) revision of 9.2.1 (Earthing) with the deletion of the word "permanently"; h) revision of Annex N: earth continuity test time; i) revision of 7.11.4; 7.14.1; Table 22 (14.4.3): Introduction of requirements for suspension by magnets; j) addition of a new Annex W for luminaires using batteries; k) clarification of Clause 6 for marking requirements for nature of supply; l) addition of a new Subclause 7.31.5: Additional requirements for luminaires using controllable controlgear providing SELV output(s); m) revision of 6.4.16: Information to be provided for luminaire having protective earth current > 10 mA; n) revision of 6.3.23; 6.4.18; 6.4.24; 7.30 and 10.2.1 for serviceable, non-user serviceable and non-serviceable components; o) revision of Annex D: Draught-proof enclosure; p) revision of 8.2.1 and 13.2.1: Inconsistencies in the inclusion of the limits of voltage ranges; q) revision of 9.2.10 for looping-in; r) Revision of Clause 2 and 7.8: update of the reference to IEC 61058-1-1, IEC 61058-1-2 and IEC 61058­2­1. Update of temperature limits in Table 21 (14.4.3) for luminaires incorporating switches according to IEC 60669-1 or IEC 60669-2-1; s) revision of 6.3.22 and 7.24 for photobiological safety; t) addition of a new Subclause 6.3.27 for marking of mains socket outlet moved from information requirements.

Need to identify, monitor and decipher standards?