IEC 60599:2015

IEC 60599:2015

September 2015
International standard Cancelled

Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis

IEC 60599:2015 describes how the concentrations of dissolved gases or free gases may be interpreted to diagnose the condition of oil-filled electrical equipment in service and suggest future action. This standard is applicable to electrical equipment filled with mineral insulating oil and insulated with cellulosic paper or pressboard-based solid insulation. Information about specific types of equipment such as transformers (power, instrument, industrial, railways, distribution), reactors, bushings, switchgear and oil-filled cables is given only as an indication in the application notes. This standard may be applied, but only with caution, to other liquid-solid insulating systems. This third edition cancels and replaces the second edition published in 1999 and Amendment 1:2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) revision of 5.5, 6.1, 7, 8, 9, 10, A.2.6, A.3, A.7;b) addition of new sub-clause 4.3;c) expansion of the Bibliography;d) revision of Figure 1;e) addition of Figure B.4.

Main informations

Collections

International IEC standards

Publication date

September 2015

Number of pages

78 p.

Reference

IEC 60599:2015
Sumary
Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis

IEC 60599:2015 describes how the concentrations of dissolved gases or free gases may be interpreted to diagnose the condition of oil-filled electrical equipment in service and suggest future action. This standard is applicable to electrical equipment filled with mineral insulating oil and insulated with cellulosic paper or pressboard-based solid insulation. Information about specific types of equipment such as transformers (power, instrument, industrial, railways, distribution), reactors, bushings, switchgear and oil-filled cables is given only as an indication in the application notes. This standard may be applied, but only with caution, to other liquid-solid insulating systems. This third edition cancels and replaces the second edition published in 1999 and Amendment 1:2007. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) revision of 5.5, 6.1, 7, 8, 9, 10, A.2.6, A.3, A.7;
b) addition of new sub-clause 4.3;
c) expansion of the Bibliography;
d) revision of Figure 1;
e) addition of Figure B.4.
Replaced standards (2)
International standard Cancelled
Amendment 1 - Mineral oil-impregnated electrical equipment in service - Guide to the interpretation of dissolved and free gases analysis

IEC 60599:1999
April 1999
International standard Cancelled
Mineral oil-impregnated electrical equipment in service - Guide to the interpretation of dissolved and free gases analysis

Describes how the concentrations of dissolved gases or free gases may be interpreted to diagnose the condition of oil-filled electrical equipment in service and suggests future action. Applicable to electrical equipment filled with mineral insulating oil and insulated with cellulosic paper or pressboard-based solid insulation. Information about specific types of equipment such as transformers (power, instrument, industrial, railways, distribution), reactors, bushings, switchgear and oil-filled cables is given only as an indication in the application notes. May be applied only with caution to other liquid-solid insulating systems. In any case, the indications obtained should be viewed only as guidance and any resulting action should be undertaken only with proper engineering judgement.

Standard replaced by (1)
IEC 60599:2022
May 2022
International standard Current
Mineral oil-filled electrical equipment in service - Guidance on the interpretation of dissolved and free gases analysis

IEC 60599:2022 describes how the concentrations of dissolved gases or free gases can be interpreted to diagnose the condition of oil-filled electrical equipment in service and suggest future action. This document is applicable to electrical equipment filled with mineral insulating oil and insulated with cellulosic paper or pressboard-based solid insulation. Information about specific types of equipment such as transformers (power, instrument, industrial, railways, distribution), reactors, bushings, switchgear and oil-filled cables is given only as an indication in the application notes. This document can be applied, but only with caution, to other liquid-solid insulating systems. In any case, the indications obtained are given only as guidance with resulting action undertaken only with proper engineering judgment.