IEC 60601-1-6:2004

IEC 60601-1-6:2004

June 2004
International standard Cancelled

Medical electrical equipment - Part 1-6: General requirements for safety - Collateral standard: Usability

Medical practice is increasingly using medical electrical equipment for observation and treatment of patients. use errors caused by inadequate medical electrical equipment usability have become an increasing cause for concern. The usability engineering process is intended to achieve reasonable usability, which in turn is intended to minimise use errors and to minimise use associated risks. Some, but not all, forms of incorrect use are amenable to control by the manufacturer. The usability engineering process is part of the process of risk control.This Collateral Standard describes a usability engineering process, and provides guidance on how to implement and execute the process to provide medical electrical equipment safety. It addresses normal use and use errors but excludes abnormal use.

Main informations

Collections

International IEC standards

Publication date

June 2004

Number of pages

73 p.

Reference

IEC 60601-1-6:2004

ICS Codes

11.040.01   Medical equipment in general

Print number

1
Sumary
Medical electrical equipment - Part 1-6: General requirements for safety - Collateral standard: Usability

Medical practice is increasingly using medical electrical equipment for observation and treatment of patients. use errors caused by inadequate medical electrical equipment usability have become an increasing cause for concern. The usability engineering process is intended to achieve reasonable usability, which in turn is intended to minimise use errors and to minimise use associated risks. Some, but not all, forms of incorrect use are amenable to control by the manufacturer. The usability engineering process is part of the process of risk control. This Collateral Standard describes a usability engineering process, and provides guidance on how to implement and execute the process to provide medical electrical equipment safety. It addresses normal use and use errors but excludes abnormal use.
Standard replaced by (1)
IEC 60601-1-6:2006
December 2006
International standard Cancelled
Medical electrical equipment - Part 1-6: General requirements for basic safety and essential performance - Collateral standard: Usability

Specifies requirements for a process to analyse, design, verify and validate the usability, as it relates to basic safety and essential performance of medical electrical equipment. This collateral standard addresses normal use and use errors but excludes abnormal use. The object of this collateral standard is to specify general requirements that are in addition to those of the general standard IEC 60601-1 and to serve as the basis for particular standards.