IEC 60601-2-17:1989/AMD1:1996

IEC 60601-2-17:1989/AMD1:1996

March 1996
International standard Cancelled

Amendment 1 - Medical electrical equipment. Part 2: Particular requirements for the safety of remote-controlled automatically-driven gamma-ray afterloading equipment

Contains modifications to IEC 601-2-17 in order to adapt this standard to IEC 601-1 second edition (1988).

Main informations

Collections

International IEC standards

Publication date

March 1996

Number of pages

15 p.

Reference

IEC 60601-2-17:1989/AMD1:1996

Print number

1
Sumary
Amendment 1 - Medical electrical equipment. Part 2: Particular requirements for the safety of remote-controlled automatically-driven gamma-ray afterloading equipment

Contains modifications to IEC 601-2-17 in order to adapt this standard to IEC 601-1 second edition (1988).
Standard replaced by (1)
IEC 60601-2-17:2004
January 2004
International standard Cancelled
Medical electrical equipment - Part 2-17: Particular requirements for the safety of automatically-controlled brachytherapy afterloading equipment

The use of afterloading equipment for brachytherapy purposes may expose patients to danger if the equipment fails to deliver the required dose to the patient, or if the equipment design does not satisfy standards of electrical and mechanical safety. The equipment may also cause danger to persons in the vicinity if the equipment itself fails to contain the radioactive source(s) adequately within the storage container(s) and/or if there are inadequacies in the design of the treatment room. This Particular Standard establishes requirements to be complied with by manufacturers in the design and construction of afterloading equipment for use in temporary brachytherapy procedures. Its purpose is to identify those features of design that are regarded, at the present time, as essential for the safe operation of such equipment. It places limits on the degradation of equipment performance beyond which it can be presumed that a fault condition exists and where an interlock then operates to return the radioactive source(s) to the storage container(s) and afterwards to prevent continued operation of the equipment.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ