IEC 60601-2-18:1996/AMD1:2000

IEC 60601-2-18:1996/AMD1:2000

July 2000
International standard Cancelled

Amendment 1 - Medical electrical equipment - Part 2-18: Particular requirements for the safety of endoscopic equipment

Main informations

Collections

International IEC standards

Publication date

July 2000

Number of pages

10 p.

Reference

IEC 60601-2-18:1996/AMD1:2000

Print number

2
Standard replaced by (1)
IEC 60601-2-18:2009
August 2009
International standard Current
Medical electrical equipment - Part 2-18: Particular requirements for the basic safety and essential performance of endoscopic equipment

IEC 60601-2-18:2009 establishes particular basic safety and essential performance requirements for endoscopic equipment. The minimum safety requirements specified in this particular standard are considered to provide for a practical degree of safety in the operation of endoscopic equipment. IEC 60601-2-18:2009 amends and supplements IEC 60601-1:2005. This third edition cancels and replaces the second edition, published in 1996, and its Amendment 1 (2000). This edition constitutes a technical revision and has been aligned or harmonized with IEC 60601-1:2005. The main changes with respect to the previous edition include: - alignment of requirements with IEC 60601-1:2005; - inclusion of essential performance requirements; - the inclusion of energized endoscopes and energized endotherapy devices used through second and subsequent punctures within the scope of the standard; - reference to IEC 60601-2-2 for the dielectric strength testing of HF energized endotherapy devices, rather than defining different tests.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ