IEC 60601-2-22:2007

IEC 60601-2-22:2007

May 2007
International standard Cancelled

Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment

Applies to the safety and essential performance of laser equipment for either surgical, therapeutic, medical diagnostic, cosmetic, or veterinary applications, intended for its use on humans or animals, classified as a class 3B or class 4 laser product as defined by 3.22 and 3.23 in IEC 60825-1, hereafter referred to as laser equipment.Throughout this International Standard, light emitting diodes (LED) are included whenever the word "laser" is used.This standard can also be applied to surgical, cosmetic, therapeutic and diagnostic laser equipment used for compensation or alleviation of disease, injury or disability.This third edition cancels and replaces the second edition of IEC 60601-2-22, published in 1995. This edition constitutes a technical revision.This third edition takes account of the recently published new editions of the General Standard IEC 60601-1 and publication IEC 60825-1. Additionally, it addresses technical and safety issues which have arisen in the time following the previous second edition.

Main informations

Collections

International IEC standards

Publication date

May 2007

Number of pages

52 p.

Reference

IEC 60601-2-22:2007
Sumary
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment

Applies to the safety and essential performance of laser equipment for either surgical, therapeutic, medical diagnostic, cosmetic, or veterinary applications, intended for its use on humans or animals, classified as a class 3B or class 4 laser product as defined by 3.22 and 3.23 in IEC 60825-1, hereafter referred to as laser equipment. Throughout this International Standard, light emitting diodes (LED) are included whenever the word "laser" is used. This standard can also be applied to surgical, cosmetic, therapeutic and diagnostic laser equipment used for compensation or alleviation of disease, injury or disability. This third edition cancels and replaces the second edition of IEC 60601-2-22, published in 1995. This edition constitutes a technical revision. This third edition takes account of the recently published new editions of the General Standard IEC 60601-1 and publication IEC 60825-1. Additionally, it addresses technical and safety issues which have arisen in the time following the previous second edition.
Replaced standards (1)
IEC 60601-2-22:1995
November 1995
International standard Cancelled
Medical electrical equipment - Part 2: Particular requirements for the safety of diagnostic and therapeutic laser equipment

Applies to laser equipment for medical applications, classified as a class 3B or class 4 laser product according to the classification in IEC 60825-1.

Standard replaced by (1)
IEC 60601-2-22:2019
November 2019
International standard Current
Medical electrical equipment - Part 2-22: Particular requirements for basic safety and essential performance of surgical, cosmetic, therapeutic and diagnostic laser equipment

IEC 60601-2-22:2019 applies to the Basic Safety and Essential Performance of laser equipment for surgical, therapeutic, medical diagnostic, cosmetic or veterinary applications, intended for use on humans or animals, classified as Laser Product of Class 1C where the Enclosed Laser is of Class 3B or 4, or Class 3B, or Class 4. Medical Electrical Equipment or Medical Electrical Systems which incorporate lasers as sources of energy being transferred to the Patient or animal and where the lasers are specified as above, are referred to as ?laser equipment? in this document. Laser Products for these applications classified as a Class 1, Class 1M, Class 2, Class 2M or Class 3R Laser Product, are covered by IEC 60825-1:2014 and by the general standard. If a clause or subclause is specifically intended to be applicable to ME Equipment only, or to ME Systems only, the title and content of that clause or subclause will say so. If that is not the case, the clause or subclause applies to ME Equipment and to ME Systems, as relevant. Hazards inherent in the intended physiological function of laser equipment within the scope of this document are not covered by specific requirements in this document except in 7.2.13, Physiological effects, of the general standard. If the laser equipment is Class 1C according to IEC 60825-1:2014 and is used as a laser appliance in a household, it is covered by IEC 60335-2-113:2016. This fourth edition cancels and replaces the third edition published in 2007 and Amendment 1:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) it takes account of IEC 60601-1:2005/AMD1:2012 and IEC 60825-1:2014, which have been published since publication of the third edition; b) it addresses technical and safety issues which have arisen since publication of the third edition; c) the scope of this fourth edition differs from the scope of the third edition. It now includes Class 1C laser equipment, as defined in IEC 60825-1:2014, when the Enclosed Laser is Class 3B or 4; d) LED (light emitting diode) products are now excluded from this document as medical LED products may be covered by IEC 60601-2-57.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ