IEC 60601-2-31:2008

IEC 60601-2-31:2008

March 2008
International standard Cancelled

Medical electrical equipment - Part 2-31: Particular requirements for the basic safety and essential performance of external cardiac pacemakers with internal power source

IEC 60601-2-31:2008 applies to the basic safety and essential performance of external pacemakers powered by an internal electrical power source. The minimum safety requirements specified in this particular standard are considered to provide for a practical degree of safety in the operation of external cardiac pacemakers with an internal power source. This particular standard amends and supplements IEC 60601-1 (third edition, 2005): Medical electrical equipment - Part 1: General requirements for basic safety and essential performance. This second edition cancels and replaces the first edition published in 1994 and its Amendment 1 (1998). This second edition of IEC 60601-2-31 is aligned with IEC 60601-1:2005, and contains minimal technical revisions from the first edition.

Main informations

Collections

International IEC standards

Publication date

March 2008

Number of pages

71 p.

Reference

IEC 60601-2-31:2008
Sumary
Medical electrical equipment - Part 2-31: Particular requirements for the basic safety and essential performance of external cardiac pacemakers with internal power source

IEC 60601-2-31:2008 applies to the basic safety and essential performance of external pacemakers powered by an internal electrical power source. The minimum safety requirements specified in this particular standard are considered to provide for a practical degree of safety in the operation of external cardiac pacemakers with an internal power source. This particular standard amends and supplements IEC 60601-1 (third edition, 2005): Medical electrical equipment - Part 1: General requirements for basic safety and essential performance. This second edition cancels and replaces the first edition published in 1994 and its Amendment 1 (1998). This second edition of IEC 60601-2-31 is aligned with IEC 60601-1:2005, and contains minimal technical revisions from the first edition.
Replaced standards (2)
International standard Cancelled
Amendment 1 - Medical electrical equipment - Part 2-31: Particular requirements for the safety of external cardiac pacemakers with internal power source

IEC 60601-2-31:1994
October 1994
International standard Cancelled
Medical electrical equipment - Part 2: Particular requirements for the safety of external cardiac pacemakers with internal power source

Specifies the particular safety requirements for external pacemakers powered by an internal electrical power source. Applies also to patient cables but does not apply to equipment which can be directly or indirectly connected to a supply mains.

Standard replaced by (1)
IEC 60601-2-31:2020
January 2020
International standard Current
Medical electrical equipment - Part 2-31: Particular requirements for the basic safety and essential performance of external cardiac pacemakers with internal power source

IEC 60601-2-31:2020 applies to the BASIC SAFETY and ESSENTIAL PERFORMANCE of EXTERNAL PACEMAKERS powered by an INTERNAL ELECTRICAL POWER SOURCE, hereafter referred to as ME EQUIPMENT. This document applies to PATIENT CABLES as defined in 201.3.209, but does not apply to LEADS as defined in 201.3.206. HAZARDS inherent in the intended physiological function of ME EQUIPMENT within the scope of this document are not covered by specific requirements in this document except in 7.2.13 and 8.4.1 of the general standard. This document does not apply to the implantable parts of ACTIVE IMPLANTABLE MEDICAL DEVICES covered by ISO 14708-1. This document does not apply to EXTERNAL PACEMAKERS which can be connected directly or indirectly to a SUPPLY MAINS. This document does not apply to transthoracic and oesophageal pacing ME EQUIPMENT and antitachycardia ME EQUIPMENT. IEC 60601-2-31:2020 cancels and replaces the second edition published in 2008 and Amendment 1:2011. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) The requirement for testing for energy reduction has been removed; b) The test for exposure to external defibrillation has been completely revised; c) The exclusion for testing ESD immunity only with respect to air discharges has been removed; d) Alignment with the latest edition of ISO 14708-2 for pacemakers, as well as the associated EMC standard ISO 14117; e) Additional rationale for all changes.