IEC 60700-1:1998

IEC 60700-1:1998

September 1998
International standard Cancelled

Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing

Applies to thyristor valves with metal oxide surge arresters directly connected between the valve terminals, for use in a line commuted commutated converter for high voltage d.c. power transmission or as part of a back-to-back link. Retricted to electrical type and production tests. Tests are based on airinsulated valves.

Main informations

Collections

International IEC standards

Publication date

September 1998

Number of pages

95 p.

Reference

IEC 60700-1:1998

ICS Codes

29.200   Rectifiers. Converters. Stabilized power supply

Print number

1
Sumary
Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing

Applies to thyristor valves with metal oxide surge arresters directly connected between the valve terminals, for use in a line commuted commutated converter for high voltage d.c. power transmission or as part of a back-to-back link. Retricted to electrical type and production tests. Tests are based on air insulated valves.
Replaced standards (1)
IEC 60700:1981
January 1981
International standard Cancelled
Testing of semiconductor valves for high-voltage d.c. power transmission

Defines terms of insulation co-ordination and valve construction. Describes methods for type tests carried out to verify that the valve design will meet the specified requirements. Covers production tests carried out to verify proper manufacture. Production tests consist of routine tests (on all valves, modules or components) and sample tests (on a small number taken at random from a batch). Appendix gives guidance for the choice of test safety factor.

Standard replaced by (1)
IEC 60700-1:2015
July 2015
International standard Current
Thyristor valves for high voltage direct current (HVDC) power transmission - Part 1: Electrical testing

IEC 60700-1:2015 applies to thyristor valves with metal oxide surge arresters directly connected between the valve terminals, for use in a line commutated converter for high voltage d.c. power transmission or as part of a back-to-back link. It is restricted to electrical type and production tests. The tests specified in this standard are based on air insulated valves. For other types of valves, the test requirements and acceptance criteria can be agreed. This edition includes the following significant technical changes with respect to the previous edition. a) Definitions of terms "redundant thyristor levels", "thyristor level", "valve section" have been changed for clarification. b) The notes were added to test requirements of dielectric d.c. voltage tests for valve support, MVU, valve, specifying that before repeating the test with opposite polarity, the tested object may be short-circuited and earthed for several hours. The same procedure may be followed at the end of the d.c. voltage test. c) Table 1 on thyristor level faults permitted during type tests was supplemented. d) The alternative MVU dielectric test method was added. e) It was specified that production tests may include routine tests as well as sample tests. f) It was added into test requirements for periodic firing and extinction tests that a scaling factor for tests shall be applied when testing with valve sections. The contents of the corrigendum of January 2017 have been included in this copy.