IEC 60704-2-13:2023

IEC 60704-2-13:2023

October 2023
International standard Current

Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-13: Particular requirements for cooking fume extractors

IEC 60704-2-13:2023 applies to cooking fume extractors for household and similar use intended for filtering the air of a room or for exhausting the air out of a room, including their accessories and their component parts. It also applies to cooking fume extractors where the fan is mounted separately from the appliance inside or outside of the room where the appliance is located, but controlled by the appliance when the fan is defined in the technical documentation. This document deals also with down-draft systems that are arranged beside, behind or under the cooking appliance.Measurements carried out in accordance with this document determine the noise emission into the room, from which cooking fumes are extracted. Noise emission to the outside (e.g. through air ducts) are not considered.This fourth edition cancels and replaces the third edition published in 2016. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:a) alignment with IEC 61591:2023;b) change of title, scope and definitions 3.103 and 3.104: this document deals with cooking fume extractors (this covers range hoods and down-draft systems);c) exhaust pipe of down-draft systems specified;d) built-in range hoods in recirculation mode with an air outlet device specified;e) alignment with IEC 60704-1:2021.This document is to be used in conjunction with IEC 60704-1:2021.

Main informations

Collections

International IEC standards

Publication date

October 2023

Number of pages

39 p.

Reference

IEC 60704-2-13:2023
Sumary
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-13: Particular requirements for cooking fume extractors

IEC 60704-2-13:2023 applies to cooking fume extractors for household and similar use intended for filtering the air of a room or for exhausting the air out of a room, including their accessories and their component parts. It also applies to cooking fume extractors where the fan is mounted separately from the appliance inside or outside of the room where the appliance is located, but controlled by the appliance when the fan is defined in the technical documentation. This document deals also with down-draft systems that are arranged beside, behind or under the cooking appliance.
Measurements carried out in accordance with this document determine the noise emission into the room, from which cooking fumes are extracted. Noise emission to the outside (e.g. through air ducts) are not considered.
This fourth edition cancels and replaces the third edition published in 2016. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment with IEC 61591:2023;
b) change of title, scope and definitions 3.103 and 3.104: this document deals with cooking fume extractors (this covers range hoods and down-draft systems);
c) exhaust pipe of down-draft systems specified;
d) built-in range hoods in recirculation mode with an air outlet device specified;
e) alignment with IEC 60704-1:2021.
This document is to be used in conjunction with IEC 60704-1:2021.
Replaced standards (1)
IEC 60704-2-13:2016
October 2016
International standard Cancelled
Household and similar electrical appliances - Test code for the determination of airborne acoustical noise - Part 2-13: Particular requirements for range hoods and other cooking fume extractors

IEC 60704-2-13:2016 This standard applies to electrical range hoods and other cooking fume extractors for household and similar use intended for filtering the air of a room or for exhausting the air out of a room, including their accessories and their component parts. It also applies to cooking fume extractors with an external fan which may be mounted inside or outside of the room where the range hood is located or a down-draft system that is arranged beside, behind or under the cooking surface. This edition includes the following significant technical changes with respect to the previous edition: a) change of title, scope and definitions 3.103 and 3.104: the standard is dealing with cooking fume extractors (this covers range hoods and down-draft systems); b) exhaust pipe of down-draft systems specified; c) built-in recirculation-air range hoods with an air outlet device specified; d) Annex AA has been deleted. This publication is to be read in conjunction with IEC 60704-1:2010.