IEC 60721-3-3:1994/AMD2:1996

IEC 60721-3-3:1994/AMD2:1996

November 1996
International standard Cancelled

Amendment 2 - Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 3: Stationary use at weatherprotected locations

Main informations

Collections

International IEC standards

Publication date

November 1996

Number of pages

8 p.

Reference

IEC 60721-3-3:1994/AMD2:1996

Print number

2 - 13/06/2005
Standard replaced by (1)
International standard Current
Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations

IEC 60721-3-3:2019 classifies groups of environmental parameters and their severities to which products are subjected when installed for stationary use at weatherprotected locations. This third edition cancels and replaces the second edition published in 1994, Amendment 1: 1995 and Amendment 2:1996. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) Clause 3: definitions aligned with IEC 60721-3-1. b) Clause 4: aligned with IEC 60721-3-1. c) Clause 5: Clause A.3 has been incorporated into Clause 5. d) Subclause 5.2: all existing climate classes have been replaced by completely new classes. The new classes are divided into two groups. The reason for the new classes is the latest revision of IEC 60721-2-1 which incorporates new climate types. e) Subclause 5.3: addition of a new class for low air pressure. f) Defined values of chemically active substances are now by reference to ISO 9223. g) Subclause 5.6: all existing classes for mechanically active substances have been replaced by completely new classes, in alignment with IEC 60721-3-1. h) Subclause 5.7: all existing classes for mechanical conditions have been replaced by completely new classes, in alignment with IEC 60721-3-1. i) Table 1: new climatic classes with new severities. j) Table 2: new class for low air pressure. k) Table 4: new mechanically active substances classes. l) Table 5: new mechanical conditions classes. m) Annex A: revised and includes a clean climatogram. n) Annex B: revised and includes the definition of seismic environment. o) All classes regarding fire, all combined classes, all chemically active substances classes, Clause A.2, Annexes C, D and E have been removed.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ