IEC 60728-11:2016
Cable networks for television signals, sound signals and interactive services - Part 11: Safety
IEC 60728-11:2016 deals with the safety requirements applicable to fixed sited systems and equipment. As far as applicable, it is also valid for mobile and temporarily installed systems, for example, caravans. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- Correction of minimum cross-section of bonding conductor in Figure 6, Figure 14 and Figure 17.- Creation of new symbols for "overvoltage protective device - (OPD)" and for "coaxial overvoltage protective device - (COPD)".- Introduction of new OPD symbol to 3.2, Figure 3 and Figure 6.- Introduction of new COPD symbol to 3.2 and Figure 19.- In 3.1 replacement of terms CATV, MATV and SMATV by new terms and definitions due to changes in technology and use of cable networks.- Extension for remote feeding voltage on subscriber feeder.- Adaption to Edition 2.0 of the IEC 62305 series.- Deletion of informative Annex C and normative reference to the simplified software for the calculation of risk due to lightning (Annex J of IEC 62305-2:2006.)- New subclause 10.2.6 Fully-isolated system outlet provided by means of a FTTH system. The contents of the corrigendum of July 2016 have been included in this copy.
IEC 60728-11:2016 deals with the safety requirements applicable to fixed sited systems and equipment. As far as applicable, it is also valid for mobile and temporarily installed systems, for example, caravans. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- Correction of minimum cross-section of bonding conductor in Figure 6, Figure 14 and Figure 17.
- Creation of new symbols for "overvoltage protective device - (OPD)" and for "coaxial overvoltage protective device - (COPD)".
- Introduction of new OPD symbol to 3.2, Figure 3 and Figure 6.
- Introduction of new COPD symbol to 3.2 and Figure 19.
- In 3.1 replacement of terms CATV, MATV and SMATV by new terms and definitions due to changes in technology and use of cable networks.
- Extension for remote feeding voltage on subscriber feeder.
- Adaption to Edition 2.0 of the IEC 62305 series.
- Deletion of informative Annex C and normative reference to the simplified software for the calculation of risk due to lightning (Annex J of IEC 62305-2:2006.)
- New subclause 10.2.6 Fully-isolated system outlet provided by means of a FTTH system. The contents of the corrigendum of July 2016 have been included in this copy.
IEC 60728-11:2010(E) deals with the safety requirements applicable to fixed sited systems and equipment. As far as applicable, it is also valid for mobile and temporarily installed systems, for example, caravans. Additional requirements may be applied. It is intended to provide specifically for the safety of the system, personnel working on it, subscribers and subscriber equipment. It deals only with safety aspects and is not intended to define a standard for the protection of the equipment used in the system. This third edition cancels and replaces the second edition published in 2005. This edition constitutes a technical revision and includes the following significant technical changes with respect to the previous edition: The list of "differences in some countries" was transferred from the "Foreword" to informative Annex D. Some new terms and definitions were added. All Figures were reworked among other things concerning equipotential bonding and earthing details and were incorporated in the text at the appropriate places. Clause 11 "Protection against atmospheric overvoltages and elimination of potential differences" was completely reworked and re-structured taking into account among other things the provisions and requirements of the IEC 62305 series on "Lightning protection". New informative Annex A on "Earth loop impedance" was added. New informative Annex C on "Examples of calculation of risk due to lightning" was added. Former Annex B on "Special conditions using IT power line networks" was re-worded and incorporated in Annex D as "Difference in Norway".
IEC 60728-11:2023 deals with the safety requirements applicable to fixed sited systems and equipment. As far as applicable, it is also valid for mobile and temporarily installed systems, for example, caravans. Additional requirements may be applied, for example, referring to: - electrical installations of buildings and overhead lines, - other telecommunication services distribution systems, - water distribution systems, - gas distribution systems, - lightning systems. This document is intended to provide requirements specifically for the safety of the system, personnel working on it, subscribers and subscriber equipment. It deals only with safety aspects and is not intended to define a standard for the protection of the equipment used in the system. IEC 60728-11:2023 cancels and replaces the fourth edition published in 2016. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition. a) Replacement of references to IEC 60065 and IEC 60950-1 with references to IEC 62368-1. b) Addition of subclauses 4.4 to 4.6. c) Revised definition of class I equipment, class II equipment, main earthing terminal, see 3.1.6, 3.1.8 and 3.1.31. d) Addition of definitions for harm, hazard, ordinary person, instructed person, skilled person, see 3.1.22, 3.1.23, 3.1.39, 3.1.40 and 3.1.41. e) Additional requirement to provide details on the equipment installed, see 4.1. f) Additional mechanical, design and construction requirements, see 4.2.2. g) Changes to the accessible part requirements, see 4.2.3. h) The current carrying capacity and dielectric strength of components is now obligatory, see 8.1.3. i) The assessment of the risk of lightning strike is now obligatory, see Figure 10. j) Extension of remote feeding voltage on subscriber feeder, see Table 1.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ