IEC 60730-2-5:2000/AMD2:2008

IEC 60730-2-5:2000/AMD2:2008

November 2008
International standard Cancelled

Amendment 2 - Automatic electrical controls for household and similar use - Part 2-5: Particular requirements for automatic electrical burner control systems

Main informations

Collections

International IEC standards

Publication date

November 2008

Number of pages

37 p.

Reference

IEC 60730-2-5:2000/AMD2:2008

Print number

3 - 17/12/2008
Standard replaced by (1)
IEC 60730-2-5:2013
November 2013
International standard Current
Automatic electrical controls - Part 2-5: Particular requirements for automatic electrical burner control systems

IEC 60730-2-5:2013 applies to automatic electrical burner control systems for the automatic control of burners for oil, gas, coal or other combustibles for household and similar use including heating, air conditioning and similar use. This part 2-5 is applicable to a complete burner control system and to a separate programming unit. This part 2-5 is also applicable to a separate electronic high-voltage ignition source and to a separate flame detector. Separate ignition devices (electrodes, pilot burners, etc.) are not covered by this part 2-5 unless they are submitted as part of a burner control system. Requirements for separate ignition transformers are contained in IEC 60989. Systems utilizing thermoelectric flame supervision are not covered by this part 2-5. This part 2-5 applies to the inherent safety, to the manufacturer's declared operating values, operating times and operating sequences where such are associated with burner safety and to the testing of automatic electrical burner control systems used in, on, or in association with, burners. It was established on the basis of the fourth edition (2010) of that publication. Consideration may be given to future editions of, or amendments to, IEC 60730-1. The title of IEC 60730-2-5 Ed4.0 has been updated to the title of IEC 60730-1 Ed5.0. However, IEC 60730-2-5 Ed4.0 has not been updated in accordance with the technical requirements in IEC 60730-1 Ed5.0. This part 2-5 supplements or modifies the corresponding clauses in IEC 60730-1 so as to convert that publication into the IEC standard: Safety requirements for automatic electrical burner control systems. Key words: Automatic control, Burner control This publication is to be read in conjunction with IEC 60730-1:2013. The contents of the corrigendum of October 2023 have been included in this copy.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ