IEC 60793-1-41:2010

IEC 60793-1-41:2010

August 2010
International standard Cancelled

Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth

IEC 60793-1-41:2010 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-30 series and IEC 60793-40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are:- Method A - Time domain (pulse distortion) measurement- Method B - Frequency-domain measurement- Method C - Overfilled launch modal bandwidth calculated from differential mode delay (OMBc).The main change with respect to the previous edition is the addition of a third method for determining modal bandwidth based on DMD data and to improve measurement procedures for A4 fibres. This standard should be read in conjunction with IEC 60793-1-1 and IEC 60793-1-2, which cover generic specifications.

Main informations

Collections

International IEC standards

Publication date

August 2010

Number of pages

59 p.

Reference

IEC 60793-1-41:2010
Sumary
Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth

IEC 60793-1-41:2010 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-30 series and IEC 60793-40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are:
- Method A - Time domain (pulse distortion) measurement
- Method B - Frequency-domain measurement
- Method C - Overfilled launch modal bandwidth calculated from differential mode delay (OMBc).
The main change with respect to the previous edition is the addition of a third method for determining modal bandwidth based on DMD data and to improve measurement procedures for A4 fibres. This standard should be read in conjunction with IEC 60793-1-1 and IEC 60793-1-2, which cover generic specifications.
Replaced standards (1)
IEC 60793-1-41:2003
April 2003
International standard Cancelled
Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth

Describes two methods for determining and measuring the modal bandwidth of multi-mode optical fibres (see IEC 60793-2-10, IEC 60793-2-30 and IEC 60793-2-40).The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidally modulated light source, it can also be measured by observing the broadening of a narrow pulse of light. Method A - Optical time domain measurement method (pulse distortion). Method 2 - Frequency domain measurement method. Each method can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition.

Standard replaced by (1)
IEC 60793-1-41:2024
April 2024
International standard Current
Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth

IEC 60793-1-41:2024 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-2-30, and the IEC 60793?2?40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are: Method A ? Time domain (pulse distortion) measurement Method B ? Frequency-domain measurement Method C ? Overfilled launch modal bandwidth calculated from differential mode delay (OMBc) Method A and method B can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition. Method C is only defined for A1-OM3 to A1-OM5 multimode fibres and uses a weighted summation of DMD launch responses with the weights corresponding to an overfilled launch condition. The relevant test method and launch condition is chosen according to the type of fibre. NOTE 1?These test methods are commonly used in production and research facilities and are not easily accomplished in the field. NOTE 2?OFL has been used for the modal bandwidth value for LED-based applications for many years. However, no single launch condition is representative of the laser (e.g. VCSEL) sources that are used for gigabit and higher rate transmission. This fact drove the development of IEC 60793-1-49 for determining the effective modal bandwidth of laser optimized 50 µm fibres. See IEC 60793-2-10 and IEC 61280-4-1 for more information. This fourth edition cancels and replaces the third edition published in 2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the addition of a direct reference for method A and method B.