IEC 60793-1-41:2003
Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth
Describes two methods for determining and measuring the modal bandwidth of multi-mode optical fibres (see IEC 60793-2-10, IEC 60793-2-30 and IEC 60793-2-40).The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidally modulated light source, it can also be measured by observing the broadening of a narrow pulse of light. Method A - Optical time domain measurement method (pulse distortion). Method 2 - Frequency domain measurement method. Each method can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition.
Describes two methods for determining and measuring the modal bandwidth of multi-mode optical fibres (see IEC 60793-2-10, IEC 60793-2-30 and IEC 60793-2-40).The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidally modulated light source, it can also be measured by observing the broadening of a narrow pulse of light. Method A - Optical time domain measurement method (pulse distortion). Method 2 - Frequency domain measurement method. Each method can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition.
IEC 60793-1-41:2010 describes three methods for determining and measuring the modal bandwidth of multimode optical fibres (see IEC 60793-2-10, IEC 60793-30 series and IEC 60793-40 series). The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidaly modulated light source. The baseband response can also be measured by observing the broadening of a narrow pulse of light. The calculated response is determined using differential mode delay (DMD) data. The three methods are: - Method A - Time domain (pulse distortion) measurement - Method B - Frequency-domain measurement - Method C - Overfilled launch modal bandwidth calculated from differential mode delay (OMBc). The main change with respect to the previous edition is the addition of a third method for determining modal bandwidth based on DMD data and to improve measurement procedures for A4 fibres. This standard should be read in conjunction with IEC 60793-1-1 and IEC 60793-1-2, which cover generic specifications.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ