Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth

Two methods are described for measuring bandwidth: impulse response and frequency response. Both methods apply to the measurement of bandwidth of category A1 multimode fibres. Application to other categories of class A multimode fibres is under study. Neither method applies to measurement of type B single-mode fibres.

Main informations

Collections

International IEC standards

Publication date

July 2001

Number of pages

25 p.

Reference

IEC 60793-1-41:2001

Print number

1
Sumary
Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth

Two methods are described for measuring bandwidth: impulse response and frequency response. Both methods apply to the measurement of bandwidth of category A1 multimode fibres. Application to other categories of class A multimode fibres is under study. Neither method applies to measurement of type B single-mode fibres.
Replaced standards (2)
International standard Cancelled
Amendment 2 - Optical fibres - Part 1: Generic specification - Section 4: Measuring methods for transmission and optical characteristics

International standard Cancelled
Amendment 1 - Optical fibres - Part 1: Generic specification - Section 4: Measuring methods for transmission and optical characteristics

Standard replaced by (1)
IEC 60793-1-41:2003
April 2003
International standard Cancelled
Optical fibres - Part 1-41: Measurement methods and test procedures - Bandwidth

Describes two methods for determining and measuring the modal bandwidth of multi-mode optical fibres (see IEC 60793-2-10, IEC 60793-2-30 and IEC 60793-2-40).The baseband frequency response is directly measured in the frequency domain by determining the fibre response to a sinusoidally modulated light source, it can also be measured by observing the broadening of a narrow pulse of light. Method A - Optical time domain measurement method (pulse distortion). Method 2 - Frequency domain measurement method. Each method can be performed using one of two launches: an overfilled launch (OFL) condition or a restricted mode launch (RML) condition.