IEC 60840:2004

IEC 60840:2004

April 2004
International standard Cancelled

Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements

Specifies test methods and requirements for power cable systems for fixed installations, for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV). It also separately covers cables and accessories.The requirements apply to single-core cables and to individually screened three-core cables and to their accessories for usual conditions of installation and operation, but not to special cables and their accessories, such as submarine cables, for which modifications to the standard tests may be necessary or special test conditions may need to be devised.This standard does not cover transition joints between cables with extruded insulation and paper insulated cables.Some countries have suggested that a better discrimination be made between systems, cables and accessories, particularly for the lower voltages of the scope, e.g. 45 kV. This has been taken into account in this revision, which gives the type approval requirements and the range of approvals fora) cable systems; b) cables alone; c) accessories alone.Manufacturers and users may choose the most appropriate option for type approval.

Main informations

Collections

International IEC standards

Publication date

April 2004

Number of pages

55 p.

Reference

IEC 60840:2004

ICS Codes

29.060.20   Cables

Print number

1
Sumary
Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements

Specifies test methods and requirements for power cable systems for fixed installations, for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV). It also separately covers cables and accessories. The requirements apply to single-core cables and to individually screened three-core cables and to their accessories for usual conditions of installation and operation, but not to special cables and their accessories, such as submarine cables, for which modifications to the standard tests may be necessary or special test conditions may need to be devised. This standard does not cover transition joints between cables with extruded insulation and paper insulated cables. Some countries have suggested that a better discrimination be made between systems, cables and accessories, particularly for the lower voltages of the scope, e.g. 45 kV. This has been taken into account in this revision, which gives the type approval requirements and the range of approvals for a) cable systems; b) cables alone; c) accessories alone. Manufacturers and users may choose the most appropriate option for type approval.
Replaced standards (1)
IEC 60840:1999
February 1999
International standard Cancelled
Power cables with extruded insulation and their accessories for rated voltages above 30 kV (Um = 36 kV) up to 150 kV (Um = 170 kV) - Test methods and requirements

Specifies test requirements for power cables with extruded insulation and their accessories for fixed installations, for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV). The requirements apply to single-core cables and to three-core cables with separate cores and to their accessories for usual conditions of installation and operation, but not to special cables and their accessories, such as submarine cables, for which modifications to the standard tests may be necessary or special test conditions may need to be devised.

Standard replaced by (1)
IEC 60840:2011
November 2011
International standard Cancelled
Power cables with extruded insulation and their accessories for rated voltages above 30 kV (<em>U</em><sub>m</sub> = 36 kV) up to 150 kV (<em>U</em><sub>m</sub> = 170 kV) - Test methods and requirements

IEC 60840:2011 specifies test methods and requirements for power cable systems, cables alone and accessories alone, for fixed installations and for rated voltages above 30 kV (Um = 36 kV) up to and including 150 kV (Um = 170 kV). The requirements apply to single-core cables and to individually screened three-core cables and to their accessories for usual conditions of installation and operation, but not to special cables and their accessories, such as submarine cables, for which modifications to the standard tests may be necessary or special test conditions may need to be devised. This standard does not cover transition joints between cables with extruded insulation and paper insulated cables. The significant technical change with respect to the previous edition is as follows: - introduction of a prequalification test procedure for cables with high electrical stresses and tested as a cable system including accessories. NOTE: For a more detailed history of events leading up to this fourth edition, see the Introduction.