IEC 60851-5:2026
Winding wires - Test methods - Part 5: Electrical properties
IEC 60851-5:2026 specifies the following tests:Test 5: Electrical resistance;Test 13: Breakdown voltage;Test 14: Continuity of insulation;Test 19: Dielectric dissipation factor;Test 23: Pin hole.For definitions and general notes on methods of test, Clause 3 of IEC 60851-1:2021 applies. This IEC 60851-5:2026 also specifies methods for determining the dissipation factor of enamelled winding wire, provided in Annex A. This fifth edition cancels and replaces the fourth edition published in 2008, Amendment 1:2011 and Amendment 2:2019. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:a) Subclauses 5.3.1 and 5.3.2 modified to expand the conductor size range for the loads applied during cylinder method testing for dielectric breakdown voltage of enameled wires and for fully insulated wires.b) Addition of subclause 6.5 for inline continuity testing of rectangular wire (under consideration).
IEC 60851-5:2026 specifies the following tests:
Test 5: Electrical resistance;
Test 13: Breakdown voltage;
Test 14: Continuity of insulation;
Test 19: Dielectric dissipation factor;
Test 23: Pin hole.
For definitions and general notes on methods of test, Clause 3 of IEC 60851-1:2021 applies. This IEC 60851-5:2026 also specifies methods for determining the dissipation factor of enamelled winding wire, provided in Annex A. This fifth edition cancels and replaces the fourth edition published in 2008, Amendment 1:2011 and Amendment 2:2019. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) Subclauses 5.3.1 and 5.3.2 modified to expand the conductor size range for the loads applied during cylinder method testing for dielectric breakdown voltage of enameled wires and for fully insulated wires.
b) Addition of subclause 6.5 for inline continuity testing of rectangular wire (under consideration).
IEC 60851-5:2008 specifies the following tests: - Test 5: Electrical resistance; - Test 13: Breakdown voltage; - Test 14: Continuity of insulation; - Test 19: Dielectric dissipation factor. Significant revisions to the previous edition include the following points: - In Subclause 5.3, the addition of the use of carbon brush electrodes for the counting discontinuities during the high voltage continuity test, as an alternative to the V-groove pulley electrode; and - Clarifications in the breakdown voltage test for round wires larger than 2,500 mm and for fibrous covered wires.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ