Plugs and socket-outlets for household and similar purposes - Part 2-6: Particular requirements for switched socket-outlets with interlock for fixed electrical installations

IEC 60884-2-6:2025 applies to switched socket-outlets with interlock for AC only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. Switched socket-outlets with interlock according to this document consist of a combination of socket-outlets according to IEC 60884?1, interlocked with a switch according to IEC 60669?1 and/or IEC 60669?2?1 supplied as a complete accessory. The rated current is limited to 16 A maximum for fixed accessories provided with screwless terminals.This document does not cover requirements for flush mounting boxes. However, it covers those requirements for surface-type mounting boxes which are necessary for the tests on socket-outlets.This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:a) alignment to IEC 60884-1, fourth edition.

Main informations

Collections

International IEC standards

Publication date

February 2025

Number of pages

18 p.

Reference

IEC 60884-2-6:2025

Print number

2
Sumary
Plugs and socket-outlets for household and similar purposes - Part 2-6: Particular requirements for switched socket-outlets with interlock for fixed electrical installations

IEC 60884-2-6:2025 applies to switched socket-outlets with interlock for AC only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors. Switched socket-outlets with interlock according to this document consist of a combination of socket-outlets according to IEC 60884?1, interlocked with a switch according to IEC 60669?1 and/or IEC 60669?2?1 supplied as a complete accessory. The rated current is limited to 16 A maximum for fixed accessories provided with screwless terminals.
This document does not cover requirements for flush mounting boxes. However, it covers those requirements for surface-type mounting boxes which are necessary for the tests on socket-outlets.
This second edition cancels and replaces the first edition published in 1997. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
a) alignment to IEC 60884-1, fourth edition.
Replaced standards (1)
IEC 60884-2-6:1997
August 1997
International standard Cancelled
Plugs and socket-outlets for household and similar purposes - Part 2-6: Particular requirements for switched socket-outlets with interlock for fixed electrical installations

Applies to switched socket-outlets with interlock for a.c. only, for fixed electrical installations, with or without earthing contact, with rated voltage above 50 V but not exceeding 440 V and a rated current not exceeding 32 A, intended for household and similar purposes, either indoors or outdoors.