IEC 60909-0:2001

IEC 60909-0:2001

July 2001
International standard Cancelled

Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents

Applicable to the calculation of short-circuit currents:- in low-voltage three-phase a.c. systems- in high-voltage three-phase a.c. systemsoperating at a nominal frequency of 50 Hz or 60 Hz.Systems at highest voltages of 550 kV and above with long transmission lines need special consideration.The contents of the corrigendum of February 2002 have been included in this copy.

Main informations

Collections

International IEC standards

Publication date

July 2001

Number of pages

137 p.

Reference

IEC 60909-0:2001

Print number

1
Sumary
Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents

Applicable to the calculation of short-circuit currents: - in low-voltage three-phase a.c. systems - in high-voltage three-phase a.c. systems operating at a nominal frequency of 50 Hz or 60 Hz. Systems at highest voltages of 550 kV and above with long transmission lines need special consideration. The contents of the corrigendum of February 2002 have been included in this copy.
Replaced standards (1)
IEC 60909:1988
May 1988
International standard Cancelled
Short-circuit current calculation in three-phase a.c. systems

This standard is applicable to the calculation of short-circuit currents: -in low-voltage three-phase a.c. systems, -in high-voltage three-phase a.c. systems with nominal voltages up to 230 kV operating at nominal frequency (50 Hz or 60 Hz). This standardized procedure is given in such a form as to facilitate as far as possible its use by non-specialist engineers.

Standard replaced by (1)
IEC 60909-0:2016
January 2016
International standard Current
Short-circuit currents in three-phase a.c. systems - Part 0: Calculation of currents

IEC 60909-0:2016 is applicable to the calculation of short-circuit currents in low-voltage three-phase AC systems, and in high-voltage three-phase AC systems, operating at a nominal frequency of 50 Hz or 60 Hz. It establishes a general, practicable and concise procedure leading to results which are generally of acceptable accuracy and deals with the calculation of short-circuit currents in the case of balanced or unbalanced short circuits. This second edition cancels and replaces the first edition published in 2001. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - contribution of windpower station units to the short-circuit current; - contribution of power station units with ful size converters to the short-circuit current; - new document structure. This publication is to be read in conjunction with IEC TR 60909-1:2002, IEC TR 60909-2:2008, IEC 60909-3:2009 and IEC TR 60909-4:2000.