IEC 60938-2:1999
Fixed inductors for electromagnetic interference suppression - Part 2: Sectional specification
IEC 60938-2:1999, applies to fixed inductors designed for electromagnetic interference suppression and which fall within the scope of the generic specification, IEC 60938-1. It is restricted to fixed inductors for which safety tests are appropriate. This implies that inductors specified according to this specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 1 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. This second edition cancels and replaces the first edition published in 1988.
IEC 60938-2:1999, applies to fixed inductors designed for electromagnetic interference suppression and which fall within the scope of the generic specification, IEC 60938-1. It is restricted to fixed inductors for which safety tests are appropriate. This implies that inductors specified according to this specification will either be connected to mains supplies, when compliance with the mandatory tests of Table 1 is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. This second edition cancels and replaces the first edition published in 1988.
Applicable to fixed inductors for radio inteference suppression which fall within the scope of the generic specification. The object of this standard is to prescribe standard requirements for electrical shock hazard protection and standard ratings and characteristics, and to select from the generic specification the appropriate methods of test and to give general performance requirements for suppression inductors.
IEC 60938-2:2021 applies to fixed inductors designed for electromagnetic interference suppression, which will be connected to an AC mains or other supply with a nominal voltage not exceeding 1 000 V AC RMS or 1 500 V DC with a nominal frequency not exceeding 400 Hz. This sectional specification is restricted to fixed inductors for which safety tests are appropriate. This implies that inductors specified according to this specification will either be connected to mains supplies, when compliance with the mandatory tests of Annex A is necessary, or used in other circuit positions where the equipment specification prescribes that some or all of these safety tests are required. The object of this document is to prescribe standard requirements for safety tests, preferred ratings and characteristics, to select from IEC 60938-1 the appropriate methods of test and to give general performance requirements for suppression inductors. This edition includes the following significant technical changes with respect to the previous edition: - the test plan for performance testing has been removed; mandatory safety tests and optional performance tests are listed in one test plan in Annex B; - requirements for Thyristor-Chokes have been withdrawn; - material requirements are harmonized with IEC 60939-3 and UL 60939-3; - AC chokes up to 1 000 V and DC chokes up to 1 500 V are now in the Scope.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ