IEC 60942:2003

IEC 60942:2003

January 2003
International standard Cancelled

Electroacoustics - Sound calibrators

Specifies the performance requirements for three classes of sound calibrator: laboratory standard (class LS), class 1 and class 2. Tolerance limits are smallest for class LS and greatest for class 2 instruments. Class LS sound calibrators are normally used only in the laboratory; class 1 and class 2 are considered as sound calibrators for field use. A class 1 sound calibrator is primarily intended for use with a class 1 sound level meter and a class 2 sound calibrator primarily with a class 2 sound level meter, as specified in IEC 61672-1.The tolerance limits for class LS sound calibrators are based on the use of a laboratory standard microphone, as specified in IEC 61094-1, for demonstrations of conformance to the requirements of this standard. The tolerance limits for class 1 and class 2 sound calibrators are based on the use of a working standard microphone, as specified in IEC 61094-4, for demonstrations of conformance to the requirements of this standard.This third edition cancels and replaces the second edition published in 1997, and its amendment 1 (2000), of which it constitutes a technical revision.

Main informations

Collections

International IEC standards

Publication date

January 2003

Number of pages

177 p.

Reference

IEC 60942:2003

ICS Codes

33.100.20   Immunity
17.140.50   Electroacoustics

Print number

1 - 13/06/2005
Sumary
Electroacoustics - Sound calibrators

Specifies the performance requirements for three classes of sound calibrator: laboratory standard (class LS), class 1 and class 2. Tolerance limits are smallest for class LS and greatest for class 2 instruments. Class LS sound calibrators are normally used only in the laboratory; class 1 and class 2 are considered as sound calibrators for field use. A class 1 sound calibrator is primarily intended for use with a class 1 sound level meter and a class 2 sound calibrator primarily with a class 2 sound level meter, as specified in IEC 61672-1. The tolerance limits for class LS sound calibrators are based on the use of a laboratory standard microphone, as specified in IEC 61094-1, for demonstrations of conformance to the requirements of this standard. The tolerance limits for class 1 and class 2 sound calibrators are based on the use of a working standard microphone, as specified in IEC 61094-4, for demonstrations of conformance to the requirements of this standard. This third edition cancels and replaces the second edition published in 1997, and its amendment 1 (2000), of which it constitutes a technical revision.
Replaced standards (2)
IEC 60942:1997
November 1997
International standard Cancelled
Electroacoustics - Sound calibrators

Specifies the performance requirements for three classes of sound calibrator. Sound calibrators are designed to produce a known effective sound pressure level or levels at a specified frequency or frequencies when coupled to specified models of microphone or specified configurations, for example, with or without protective grid.

International standard Cancelled
Amendment 1 - Electroacoustics - Sound calibrators

Specifies requirements for sound calibrators with respect to their immunity to power- and radio-frequency fields and to electrostatic discharge, and the permitted radio-frequency emissions, together with the test procedures to demonstrate conformance to the specifications of this standard.

Standard replaced by (1)
IEC 60942:2017
November 2017
International standard Current
Electroacoustics - Sound calibrators

IEC 60942:2017 specifies the performance requirements for three classes of sound calibrator: class LS (Laboratory Standard), class 1 and class 2. Acceptance limits are smallest for class LS and greatest for class 2 instruments. Class LS sound calibrators are normally used only in the laboratory; class 1 and class 2 are considered as sound calibrators for field use. A class 1 sound calibrator is primarily intended for use with a class 1 sound level meter and a class 2 sound calibrator primarily with a class 2 sound level meter, as specified in IEC 61672-1. The acceptance limits for class LS sound calibrators are based on the use of a laboratory standard microphone, as specified in IEC 61094-1, for demonstrations of conformance to the requirements of this document. The acceptance limits for class 1 and class 2 sound calibrators are based on the use of a working standard microphone, as specified in IEC 61094-4, for demonstrations of conformance to the requirements of this document. This fourth edition cancels and replaces the third edition published in 2003, of which it constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) deletion of the class designations, class LS/C, class 1/C and class 2/C; b) addition of two further class designations, class LS/M and class 1/M, specifically for pistonphones; c) addition of an amended criterion for assessing conformance to a specification: conformance is now demonstrated when (a) measured deviations from design goals do not exceed the applicable acceptance limits and (b) the uncertainty of measurement does not exceed the corresponding maximum-permitted uncertainty; d) modification to the short-term level fluctuation test of the sound pressure level stability; e) change to some environmental test conditions to avoid icing; f) addition of an alternative test for immunity to radio-frequency fields using transverse electromagnetic (TEM) waveguides.