IEC 60947-5-1:2003

IEC 60947-5-1:2003

November 2003
International standard Cancelled

Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices

Applies to control circuit devices and switching elements intended for control-ling, signalling, interlocking, etc., of switchgear and controlgear.It applies to control circuit devices having a rated voltage not exceeding 1 000 V a.c. (at a frequency not exceeding 1 000 Hz) or 600 V d.c.This standard applies to specific types of control circuit devices such as:- manual control switches, for example pushbuttons, rotary switches, foot switches, etc.;- electromagnetically operated control switches, either time-delayed or instantaneous, for example contactor relays;- pilot switches, for example pressure switches, temperature sensitive switches (thermostats), programmers, etc.;- position switches, for example control switches operated by part of a machine or mechanism;- associated control circuit equipment, for example indicator lights, etc.It also applies to specific types of switching elements associated with other devices (whose main circuits are covered by other standards) such as:- auxiliary contacts of a switching device (e.g. contactor, circuit breaker. etc.) which are not dedicated exclusively for use with the coil of that device;- interlocking contacts of enclosure doors;- control circuit contacts of rotary switches;- control circuit contacts of overload relays.Contactor relays shall also meet the requirements and tests of IEC 60947-4-1 except for the utilization category which shall comply with this standard.This standard does not include the relays covered in IEC 60255 or automatic electrical control devices for household and similar purposes.The colour requirements of indicator lights, pushbuttons, etc., are found in IEC 60073 and also in publication 2 of the International Commission of Illumination (CIE).The object of this standard is to state:a) The characteristics of control circuit devices.b) The electrical and mechanical requirements with respect to:1) The various duties to be performed. 2) The significance of the rated characteristics and of the markings.3) The tests to verify the rated characteristics.c) The functional requirements to be satisfied by the control circuit devices with respect to:1) Environmental conditions, including those of enclosed equipment.2) Dielectric properties.3) Terminals.The provisions of the general rules, IEC 60947-1, are applicable to this standard, where specifically called for

Main informations

Collections

International IEC standards

Publication date

November 2003

Number of pages

177 p.

Reference

IEC 60947-5-1:2003

Print number

3
Sumary
Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices

Applies to control circuit devices and switching elements intended for control-ling, signalling, interlocking, etc., of switchgear and controlgear. It applies to control circuit devices having a rated voltage not exceeding 1 000 V a.c. (at a frequency not exceeding 1 000 Hz) or 600 V d.c. This standard applies to specific types of control circuit devices such as: - manual control switches, for example pushbuttons, rotary switches, foot switches, etc.; - electromagnetically operated control switches, either time-delayed or instantaneous, for example contactor relays; - pilot switches, for example pressure switches, temperature sensitive switches (thermostats), programmers, etc.; - position switches, for example control switches operated by part of a machine or mechanism; - associated control circuit equipment, for example indicator lights, etc. It also applies to specific types of switching elements associated with other devices (whose main circuits are covered by other standards) such as: - auxiliary contacts of a switching device (e.g. contactor, circuit breaker. etc.) which are not dedicated exclusively for use with the coil of that device; - interlocking contacts of enclosure doors; - control circuit contacts of rotary switches; - control circuit contacts of overload relays. Contactor relays shall also meet the requirements and tests of IEC 60947-4-1 except for the utilization category which shall comply with this standard. This standard does not include the relays covered in IEC 60255 or automatic electrical control devices for household and similar purposes. The colour requirements of indicator lights, pushbuttons, etc., are found in IEC 60073 and also in publication 2 of the International Commission of Illumination (CIE). The object of this standard is to state: a) The characteristics of control circuit devices. b) The electrical and mechanical requirements with respect to: 1) The various duties to be performed. 2) The significance of the rated characteristics and of the markings. 3) The tests to verify the rated characteristics. c) The functional requirements to be satisfied by the control circuit devices with respect to: 1) Environmental conditions, including those of enclosed equipment. 2) Dielectric properties. 3) Terminals. The provisions of the general rules, IEC 60947-1, are applicable to this standard, where specifically called for
Standard replaced by (1)
International standard Cancelled
Low-voltage switchgear and controlgear - Part 5-1: Control circuit devices and switching elements - Electromechanical control circuit devices

IEC 60947-5-1:2016 applies to control circuit devices and switching elements intended for controlling, signalling, interlocking, etc., of switchgear and controlgear. It applies to control circuit devices having a rated voltage not exceeding 1 000 V a.c. (at a frequency not exceeding 1 000 Hz) or 600 V d.c. This fourth edition cancels and replaces the third edition published in 2003 and its Amendment 1:2009. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) update of normative references; b) update and restructuration of subclauses in 7.1; c) addition of material requirements and test; d) udpate of EMC requirements; e) clarification of requirements and update of 8.2; f) addition of requirements for screwless-type clamping units; g) udpate of existing Tables 4 and 5; h) addition of new Tables 6, 7, 8 and 9; i) addition of a new Figure 10 ; j) addition of a new Annex N. This publication is to be read in conjunction with IEC 60947-1:2007. The contents of the corrigendum of July 2016 and the corrigendum of April 2020 have been included in this copy.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ