IEC 60947-6-1:2021

IEC 60947-6-1:2021

March 2021
International standard Cancelled

Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment

IEC 60947-6-1:2021 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.This third edition cancels and replaces the second edition published in 2005, and its Amendment 1:2013. This edition constitutes a technical revision.This edition includes the following significant technical changes with respect to the previous edition:– clarification of scope and object;– clarification of terms and definitions;– removal of unnecessary definitions;– modification of characteristics;– modification of utilization categories definitions;– introduction of new markings requirements;– addition of new requirements for clearances and creepage distances;– addition of new requirements and tests for mechanical and electrical interlocks;– clarification of transfer sequences;– modification of requirements for rated short-time withstand currents;– modification of new requirements for electromagnetic compatibility;– clarification of performance requirements for CB type TSE, in alignment with requirements stated in IEC 60947-2;– addition of new test sequence V: Critical load current performance of equipment with DC ratings.

Main informations

Collections

International IEC standards

Publication date

March 2021

Number of pages

121 p.

Reference

IEC 60947-6-1:2021

ICS Codes

29.130.20   Low voltage switchgear and controlgear
29.120.40   Switches
Sumary
Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment

IEC 60947-6-1:2021 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC.
This third edition cancels and replaces the second edition published in 2005, and its Amendment 1:2013. This edition constitutes a technical revision.
This edition includes the following significant technical changes with respect to the previous edition:
– clarification of scope and object;
– clarification of terms and definitions;
– removal of unnecessary definitions;
– modification of characteristics;
– modification of utilization categories definitions;
– introduction of new markings requirements;
– addition of new requirements for clearances and creepage distances;
– addition of new requirements and tests for mechanical and electrical interlocks;
– clarification of transfer sequences;
– modification of requirements for rated short-time withstand currents;
– modification of new requirements for electromagnetic compatibility;
– clarification of performance requirements for CB type TSE, in alignment with requirements stated in IEC 60947-2;
– addition of new test sequence V: Critical load current performance of equipment with DC ratings.
Replaced standards (2)
IEC 60947-6-1:2005
September 2005
International standard Cancelled
Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment

This part of IEC 60947applies to transfer switching equipment (TSE) to be used in power systems with interruption of the supply to the load during transfer, the rated voltage of which does not exceed 1 000 V a.c. or 1 500 V d.c.

International standard Cancelled
Amendment 1 - Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment

Standard replaced by (1)
IEC 60947-6-1:2026
April 2026
International standard Current
Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment

IEC 60947-6-1:2026 is available as IEC 60947-6-1:2026 RLV which contains the International Standard and its Redline version, showing all changes of the technical content compared to the previous edition. IEC 60947-6-1:2026 applies to transfer switching equipment (TSE), to be used in power systems for ensuring the continuity of the supply and allowing the energy management of the installation, by transferring a load between power supply sources, the rated voltage of which does not exceed 1 000 V AC or 1 500 V DC. Specific requirements for bypass/isolation transfer switch equipment are given in Annex C, ATSE having closed transition capability are given in Annex D, stand-alone ATS controllers are given in Annex E, and TSE for electric driven fire pump controllers are given in Annex F. It covers: - manually operated transfer switching equipment (MTSE); - remotely operated transfer switching equipment (RTSE); - automatic transfer switching equipment (ATSE), including the controller; - stand-alone ATS controllers; - bypass/isolation transfer switch equipment (BTSE); - ATSE having closed transition capability; - fire pump TSE. It does not cover: - TSE configurations that are not fully manufacturer type tested or marked according to this document as a complete transfer switch; - auxiliary contacts (for guidance, see IEC 60947-5-1); - transfer switches used in explosive atmospheres (for guidance, see IEC 60079 (all parts)); - embedded software design (for guidance, see IEC TR 63201); - cybersecurity aspects (for guidance, see IEC 63208); - TSE rated for direct-on-line starting asynchronous motor of design NE and HE, according to IEC 60034-12. (for guidance, see AC-3e utilisation category according to IEC 60947 4 1); - other types of TSE under consideration including overlapping neutral TSE, multi-source TSE (i.e. TSE with more than two sources of supply), TSE with load-shedding functions, bus-tie TSE, and hybrid TSE; - static transfer switches covered by IEC 62310 series. This fourth edition cancels and replaces the third edition published in 2021. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: - clarification of scope; - clarification of terms and definitions; - Annex C for Bypass/Isolation Transfer Switch Equipment; - Annex D for ATSE having closed transition capability; - Annex E for Stand-alone ATS controller; - Annex F for TSE used with electric driven fire pump control equipment.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ