IEC 60974-6:2015
Arc welding equipment - Part 6: Limited duty equipment
IEC 60974-6:2015 specifies safety and performance requirements applicable to limited duty arc welding and cutting power sources and auxiliaries designed for use by laymen. Electrically powered equipment is intended to be connected to the single phase public low-voltage supply system. Engine driven power sources cannot exceed output power of 7,5 kVA. This third edition cancels and replaces the second edition published in 2010. It constitutes a technical revision. The main significant technical changes with respect to the previous edition are the following:- modified measurement conditions (see 7.3.1);- improved values for temperature limits according to the class of insulation (see Table 1);- improved maximum temperature limits (see Table 2);- deleted overload test.This publication is to be read in conjunction with IEC 60974-1:2012.
IEC 60974-6:2015 specifies safety and performance requirements applicable to limited duty arc welding and cutting power sources and auxiliaries designed for use by laymen. Electrically powered equipment is intended to be connected to the single phase public low-voltage supply system. Engine driven power sources cannot exceed output power of 7,5 kVA. This third edition cancels and replaces the second edition published in 2010. It constitutes a technical revision. The main significant technical changes with respect to the previous edition are the following:
- modified measurement conditions (see 7.3.1);
- improved values for temperature limits according to the class of insulation (see Table 1);
- improved maximum temperature limits (see Table 2);
- deleted overload test.
This publication is to be read in conjunction with IEC 60974-1:2012.
IEC 60974-6:2010 specifies safety and performance requirements applicable to limited duty arc welding and cutting power sources, and auxiliaries designed for use by laymen. Electrically powered equipment is intended to be connected to the single phase public low-voltage supply system. Engine driven power sources can not exceed output power of 7,5 kVA. This second edition cancels and replaces the first edition published in 2003. It constitutes a technical revision. The main significant technical changes with respect to the previous edition are the following: - extension of the scope; - amendment of the title; - touch current at fault condition (see 6.3.7); - new definition of thermal requirements based two independent devices, one for thermal protection and one for thermal control (see 7.1); - new definition for thermal performances at 20 °C (see 7.2); - thermal safety requirements are based on operating temperature for normal condition and maximum temperature in overload condition (see 7.4); - addition of abnormal operation test for thermal control device (see 10.4); - new requirement for auxiliaries (see Clause 16); - new rating plate definition (see Clause 17); - introduction of new mandatory warning symbols (see 12.1.117.3, Box 17b) and 19.2); - induced changes due to publication of IEC 60974-1:2005. This publication is to be read in conjunction with IEC 60974-1:2005.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ