IEC 61000-6-3:2020

IEC 61000-6-3:2020

July 2020
International standard Cancelled

Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

IEC 61000-6-3:2020 is a generic EMC emission standard applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) alternative method for measuring conducted emissions on DC ports;b) limits and requirements applicable only to equipment intended to be used in residential locations;c) more stringent limits for DC power ports.NOTE 1 Safety considerations are not covered by this document.NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document.NOTE 4 As the requirements in this document are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this document comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.

Main informations

Collections

International IEC standards

Publication date

July 2020

Number of pages

52 p.

Reference

IEC 61000-6-3:2020

ICS Codes

33.100.10   Emission
Sumary
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential environments

IEC 61000-6-3:2020 is a generic EMC emission standard applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.14) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial environments are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. The conducted and radiated emission requirements in the frequency range up to 400 GHz are considered essential and have been selected to provide an adequate level of protection of radio reception in the defined electromagnetic environment. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The emission requirements in this document are not intended to be applicable to the intentional transmissions and their harmonics from a radio transmitter as defined by the ITU. This third edition cancels and replaces the second edition published in 2006 and its Amendment 1:2010. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) alternative method for measuring conducted emissions on DC ports;
b) limits and requirements applicable only to equipment intended to be used in residential locations;
c) more stringent limits for DC power ports.
NOTE 1 Safety considerations are not covered by this document.
NOTE 2 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 3 Disturbances generated in fault conditions of equipment are not covered by this document.
NOTE 4 As the requirements in this document are more stringent or equivalent to those requirements in IEC 61000-6-4 and IEC 61000-6-8, equipment fulfilling the requirements of this document comply with the requirements of IEC 61000-6-4 and IEC 61000-6-8.
Replaced standards (2)
IEC 61000-6-3:2006
July 2006
International standard Cancelled
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments

This part of IEC 61000 for EMC emission requirements applies to electrical and electronic apparatus intended for use in residential, commercial and light-industrial environments. Emission requirements in the frequency range 0 Hz to 400 GHz are covered. No measurement needs to be performed at frequencies where no requirement is specified. This generic EMC emission standard is applicable if no relevant dedicated product or product-family EMC emission standard exists. This standard applies to apparatus intended to be directly connected to a low-voltage public mains network or connected to a dedicated DC source, which is intended to interface between the apparatus and the low-voltage public mains network. This standard applies also to apparatus which is battery operated or is powered by a non-public, but non-industrial, low-voltage power distribution system if this apparatus is intended to be used in the locations described below. The environments encompassed by this standard are residential, commercial and light-industrial locations, both indoor and outdoor. The following list, although not comprehensive, gives an indication of locations that are included: - residential properties, for example houses, apartments; - retail outlets, for example shops, supermarkets; - business premises, for example offices, banks; - areas of public entertainment, for example cinemas, public bars, dance halls; - outdoor locations, for example petrol stations, car parks, amusement and sports centres; - light-industrial locations, for example workshops, laboratories, service centres. Locations that are characterised by being supplied directly at low voltage from the public mains network are considered to be residential, commercial or light-industrial. The object of this standard is to define the emission test requirements for apparatus defined in the scope in relation to continuous and transient, conducted and radiated disturbances. The emission requirements have been selected so as to ensure that disturbances generated by apparatus operating normally in residential, commercial and light-industrial locations do not exceed a level which could prevent other apparatus from operating as intended. Fault conditions of apparatus are not taken into account. Not all disturbance phenomena have been included for testing purposes in this standard but only those considered as relevant for the equipment covered by this standard. These requirements represent essential electromagnetic compatibility emission requirements. Requirements are specified for each port considered.

International standard Cancelled
Amendment 1 - Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments

Standard replaced by (1)
IEC 61000-6-3:2026
April 2026
International standard Current
Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for equipment in residential locations

IEC 61000-6-3:2026 is applicable only if no relevant dedicated product or product family EMC emission standard has been published. This part of IEC 61000 for emission requirements applies to electrical and electronic equipment intended for use at residential (see 3.1.21) locations. This part of IEC 61000 also applies to electrical and electronic equipment intended for use at other locations that do not fall within the scope of IEC 61000-6-8 or IEC 61000-6-4. The intention is that all equipment used in the residential, commercial and light-industrial locations are covered by IEC 61000-6-3 or IEC 61000-6-8. If there is any doubt the requirements in IEC 61000-6-3 apply. Equipment that has a radio function (3.1.20) are included in the scope of this document. However, the emission requirements in this document are not intended to be applicable to the intentional transmissions from these radio transmitters, their harmonics and their out of band emissions. Not all disturbance phenomena have been included for testing purposes but only those considered relevant for the equipment intended to operate within the locations included within this document. The objectives of this document are: - to establish requirements that provide an adequate level of protection of radio reception in the frequency range 9 kHz to 400 GHz; - to establish requirements that provide an adequate level of protection against conducted and radiated electromagnetic disturbances emitted by equipment in the scope of this document; - to support the reproducibility of measurement and the repeatability of results. NOTE 1 In special cases, situations will arise where the levels specified in this document will not offer adequate protection; for example, where a sensitive receiver is used in close proximity to an equipment. In these instances, special mitigation measures can be employed. NOTE 2 Disturbances generated in fault conditions of equipment are not covered by this document. NOTE 3 The requirements in this document are more stringent or equivalent to the requirements specified in IEC 61000-6-4 and IEC 61000-6-8. This fourth edition cancels and replaces the third edition published in 2020. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) the addition of magnetic field emission requirements, including the measurement of WPT function; b) the extension of low-voltage AC mains power requirements to cover the range 9 kHz to 150 kHz; c) products with a radio function have been added to the scope; d) limits in a FAR for rack mounted equipment have been added.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ