IEC 61010-2-061:2018

IEC 61010-2-061:2018

September 2018
International standard Current

Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization

IEC 61010-2-061:2018 applies to electrically powered laboratory atomic spectro­meters with thermal atomization. It has the status of a group safety publication in accordance with IEC Guide 104. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:- adaptation of changes introduced by Amendment 1 of IEC 61010-1;- added tolerance for stability of AC voltage test equipment to Clause 6;- added requirement for interlock systems containing electric/electronic or programmable components to Clause 15.

Main informations

Collections

International IEC standards

Publication date

September 2018

Number of pages

37 p.

Reference

IEC 61010-2-061:2018
Sumary
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization

IEC 61010-2-061:2018 applies to electrically powered laboratory atomic spectro­meters with thermal atomization. It has the status of a group safety publication in accordance with IEC Guide 104. This fourth edition cancels and replaces the third edition published in 2015. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
- adaptation of changes introduced by Amendment 1 of IEC 61010-1;
- added tolerance for stability of AC voltage test equipment to Clause 6;
- added requirement for interlock systems containing electric/electronic or programmable components to Clause 15.
Replaced standards (1)
International standard Cancelled
Safety requirements for electrical equipment for measurement, control and laboratory use - Part 2-061: Particular requirements for laboratory atomic spectrometers with thermal atomization and ionization

IEC 61010-2-061:2015 applies to electrically powered laboratory atomic spectrometers with thermal atomization. It has the status of a group safety publication in accordance with IEC Guide 104. This third edition cancels and replaces the second edition published in 2003. It constitutes a technical revision and includes the following change from the second edition: - exclusion of equipment, whose size and weight make unintentional movement unlikely, from the drop test in Clause 8. - notes have been re-phrased according to ISO/IEC Directives. This publication is to be read in conjunction with IEC 61010-1:2010.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ