IEC 61300-2-11:2023

IEC 61300-2-11:2023

November 2023
International standard Current

Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-11: Tests - Axial compression

IEC 61300-2-11:2023 is to ensure that the captivation or the attachment of the cable to the fibre optic devices or components, for example fibre optic closures, will withstand compressive axial loads likely to be applied during normal service. This third edition cancels and replaces the second edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:a) added Terms and definitions clause;b) removed severity table for closures;c) added recommended severity for tubes and cables without strength member attachment.

Main informations

Collections

International IEC standards

Publication date

November 2023

Number of pages

17 p.

Reference

IEC 61300-2-11:2023
Sumary
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-11: Tests - Axial compression

IEC 61300-2-11:2023 is to ensure that the captivation or the attachment of the cable to the fibre optic devices or components, for example fibre optic closures, will withstand compressive axial loads likely to be applied during normal service. This third edition cancels and replaces the second edition published in 2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition:
a) added Terms and definitions clause;
b) removed severity table for closures;
c) added recommended severity for tubes and cables without strength member attachment.
Replaced standards (1)
IEC 61300-2-11:2012
November 2012
International standard Cancelled
Fibre optic interconnecting devices and passive components - Basic test and measurement procedures - Part 2-11: Tests - Axial compression

IEC 61300-2-11:2012 ensures that the captivation or the attachment of the cable to the fibre optic devices such as fibre optic closures will withstand compressive axial loads likely to be applied during normal service. This second edition cancels and replaces the first edition published in 1995. It constitutes a technical revision. The changes with respect to the previous edition are as follows: - the procedure and details to be specified have been reconsidered; - the severity of the test has been modified according to the cable diameter; - the apparatus and mount for the device under test have been reconsidered in the sense of clamping device placement and this datum has been indicated in an appropriate figure. Key words: compressive axial loads