IEC 61322:2020

IEC 61322:2020

January 2020
International standard Current

Radiation protection instrumentation - Installed ambient dose equivalent rate meters, warning and monitoring assemblies for neutrons with energies from thermal to 20 MeV

IEC 61322:2020 applies to installed dose equivalent rate meters, warning assemblies and monitors, as defined below. It covers equipment intended to measure neutron radiation in dose equivalent rates in the energy region between thermal and 20 MeV for the purposes of radiation protection.Assemblies of this type are commonly defined as area radiation monitors. They are normally employed to determine continuously the radiological situation in working areas in which the radiation field may change with time, for example, nuclear power plants, particle accelerators, high-activity laboratories, fuel reprocessing plants, etc., and provide alarms when the radiation field goes outside predetermined limits.The assemblies considered in this document comprise at least: a detector assembly, which may, for example, consist of a detector probe (for thermal neutrons such as BF3 proportional counter, 3He proportional counter, 6LiI(Tl) scintillation detector, etc.) and a moderating and absorbing medium surrounding the detector; a processing assembly, which may be fitted into a centralized panel, which, in the case of warning assemblies and monitors, provides signal outputs and contacts capable of activating alarm or other trip circuits; alternatively, the case when all the processing electronics are placed within the detection unit (so called "smart blocks") may be considered. In this case the functions of the processing assembly will be composed of only the indication, the providing signal outputs and contacts.This second edition cancels and replaces the first edition published in 1994This edition includes the following significant technical changes with respect to the previous edition: this document has been updated to take account of the requirements of the relevant IEC standards, IEC 60532:2010 and IEC 61005:2014.

Main informations

Collections

International IEC standards

Publication date

January 2020

Number of pages

107 p.

Reference

IEC 61322:2020
Sumary
Radiation protection instrumentation - Installed ambient dose equivalent rate meters, warning and monitoring assemblies for neutrons with energies from thermal to 20 MeV

IEC 61322:2020 applies to installed dose equivalent rate meters, warning assemblies and monitors, as defined below. It covers equipment intended to measure neutron radiation in dose equivalent rates in the energy region between thermal and 20 MeV for the purposes of radiation protection.
Assemblies of this type are commonly defined as area radiation monitors. They are normally employed to determine continuously the radiological situation in working areas in which the radiation field may change with time, for example, nuclear power plants, particle accelerators, high-activity laboratories, fuel reprocessing plants, etc., and provide alarms when the radiation field goes outside predetermined limits.
The assemblies considered in this document comprise at least:
  • a detector assembly, which may, for example, consist of a detector probe (for thermal neutrons such as BF3 proportional counter, 3He proportional counter, 6LiI(Tl) scintillation detector, etc.) and a moderating and absorbing medium surrounding the detector;
  • a processing assembly, which may be fitted into a centralized panel, which, in the case of warning assemblies and monitors, provides signal outputs and contacts capable of activating alarm or other trip circuits;
  • alternatively, the case when all the processing electronics are placed within the detection unit (so called "smart blocks") may be considered. In this case the functions of the processing assembly will be composed of only the indication, the providing signal outputs and contacts.

This second edition cancels and replaces the first edition published in 1994This edition includes the following significant technical changes with respect to the previous edition:

  • this document has been updated to take account of the requirements of the relevant IEC standards, IEC 60532:2010 and IEC 61005:2014.
Replaced standards (1)
IEC 61322:1994
December 1994
International standard Cancelled
Radiation protection instrumentation - Installed dose equivalent rate meters, warning assemblies and monitors for neutron radiation of energy from thermal to 15 MeV

Applies to installed dose equivalent rate meters, warning assemblies and monitors, and covers equipment intended to measure neutron radiation in dose equivalent quantities of energy between thermal and 15 MeV for the purposes of radiation protection.

ZOOM ON ... the Requirements department
To comply with a standard, you need to quickly understand its issues in order to determine its impact on your activity.

The Requirements department helps you quickly locate within the normative text:
- mandatory clauses to satisfy,
- non-essential but useful clauses to know, such as permissions and recommendations.

The identification of these types of clauses is based on the document “ISO / IEC Directives, Part 2 - Principles and rules of structure and drafting of ISO documents ”as well as on a constantly enriched list of verbal forms.

With Requirements, quickly access the main part of the normative text!

With Requirements, quickly access the main part of the normative text!
Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ