IEC 61340-3-1:2006
Electrostatics - Part 3-1: Methods for simulation of electrostatic effects - Human body model (HBM) electrostatic discharge test waveforms
Describes the discharge current waveforms used to simulate human body model (HBM) electrostatic discharges (ESD) and the basic requirements for equipment used to develop and verify these waveforms. This standard covers HBM ESD waveforms for use in general test methods and for application to materials or objects, electronic components and other items for ESD withstand-test or performance-evaluation purposes. The specific application of these HBM ESD waveforms to non-powered semiconductor devices is covered in IEC 60749-26. The waveforms defined in this standard are not intended for use in the testing of powered electronic systems for electromagnetic compatibility (EMC), which is covered in IEC 61000-4-2. The major change of this document is that it no longer contains the application to semiconductor devices
Describes the discharge current waveforms used to simulate human body model (HBM) electrostatic discharges (ESD) and the basic requirements for equipment used to develop and verify these waveforms. This standard covers HBM ESD waveforms for use in general test methods and for application to materials or objects, electronic components and other items for ESD withstand-test or performance-evaluation purposes. The specific application of these HBM ESD waveforms to non-powered semiconductor devices is covered in IEC 60749-26. The waveforms defined in this standard are not intended for use in the testing of powered electronic systems for electromagnetic compatibility (EMC), which is covered in IEC 61000-4-2. The major change of this document is that it no longer contains the application to semiconductor devices
Describes the discharge current waveforms used to define the HBM and the basic equipment requirements used to develop these waveforms. Test parameters are defined for testing and classifying the electrostatic discharge (ESD) sensitivity of non-powered devices to the HBM. The purpose of this standard is to establish a test model that will replicate HBM failures and will define the HBM transient current discharge waveform and all necessary test parameters to ensure reliable, reproducible test results. Reproducible data will allow accurate comparisons of HBM ESD sensitivity levels.
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ