IEC 61340-4-4:2005

IEC 61340-4-4:2005

October 2005
International standard Cancelled

Electrostatics - Part 4-4: Standard test methods for specific applications - Electrostatic classification of flexible intermediate bulk containers (FIBC)

Describes procedures for evaluating the ignition risk presented by electrostatic discharges from FIBC to flammable or explosive environments.The requirements of this standard are applicable to all types of FIBC, tested as manufactured, prior to usage, intended for use without liners in flammable or explosive environments with minimum ignition energy of more than 0,14 mJ, and where the charging currents do not exceed 3,0 A.NOTE 0,14 mJ is the minimum ignition energy normally quoted for methanol. Although more sensitive materials exist, methanol has the lowest minimum ignition energy of any material that is likely to be present when FIBC are emptied. 3,0 uA is the highest charging current likely to be found in common industrial processes. This combination of minimum ignition energy and charging current represents the most severe conditions that might be expected in practice.Compliance with the requirements of this standard does not mitigate the need for full risk assessment.The test methods included in this standard may be used in association with other performance requirements, for example when a risk assessment has shown the minimum ignition energy of concern is less than 0,14 mJ or charging currents greater than 3,0 uA are present.

Main informations

Collections

International IEC standards

Thematics

QSE, Gestion des risques et SST, Sécurité

Publication date

October 2005

Number of pages

51 p.

Reference

IEC 61340-4-4:2005

ICS Codes

29.020   Electrical engineering in general
17.220.99   Other standards related to electricity and magnetism
55.080   Sacks. Bags

Print number

1
Sumary
Electrostatics - Part 4-4: Standard test methods for specific applications - Electrostatic classification of flexible intermediate bulk containers (FIBC)

Describes procedures for evaluating the ignition risk presented by electrostatic discharges from FIBC to flammable or explosive environments. The requirements of this standard are applicable to all types of FIBC, tested as manufactured, prior to usage, intended for use without liners in flammable or explosive environments with minimum ignition energy of more than 0,14 mJ, and where the charging currents do not exceed 3,0 A. NOTE 0,14 mJ is the minimum ignition energy normally quoted for methanol. Although more sensitive materials exist, methanol has the lowest minimum ignition energy of any material that is likely to be present when FIBC are emptied. 3,0 uA is the highest charging current likely to be found in common industrial processes. This combination of minimum ignition energy and charging current represents the most severe conditions that might be expected in practice. Compliance with the requirements of this standard does not mitigate the need for full risk assessment. The test methods included in this standard may be used in association with other performance requirements, for example when a risk assessment has shown the minimum ignition energy of concern is less than 0,14 mJ or charging currents greater than 3,0 uA are present.
Standard replaced by (1)
IEC 61340-4-4:2012
January 2012
International standard Cancelled
Electrostatics - Part 4-4: Standard test methods for specific applications - Electrostatic classification of flexible intermediate bulk containers (FIBC)

IEC 61340-4-4:2012 specifies requirements for flexible intermediate bulk containers (FIBC) between 0,25 m3 and 3 m3 in volume, intended for use in hazardous explosive atmospheres. The explosive atmosphere may be created by the contents in the FIBC or may exist outside the FIBC. The requirements include: - classification and labelling of FIBC; - classification of inner liners; - specification of test methods for each type of FIBC and inner liner; - design and performance requirements for FIBC and inner liners; - safe use of FIBC (including those with inner liners) within different zones defined for explosion endangered environments, described for areas where combustible dusts are, or may be, present (IEC 60079-10-2), and for explosive gas atmospheres (IEC 60079-10-1); - procedures for type qualification and certification of FIBC, including the safe use of inner liners. The requirements of this standard are applicable to all types of FIBC and inner liners, tested as manufactured, prior to use and intended for use in hazardous explosive atmospheres: Zones 1 and 2 (Groups IIA and IIB only) and Zones 21 and 22. For some types of FIBC, the requirements of this standard apply only to use in hazardous explosive atmospheres with minimum ignition energy of 0,14 mJ or greater and where charging currents do not exceed 3,0 μA. Compliance with the requirements specified in this standard does not necessarily ensure that hazardous electrostatic discharges, e.g. cone discharges, will not be generated by the contents in FIBC. Compliance with the requirements of this standard does not mitigate the need for full risk assessment. For example, metal and other conductive powders and toner powders may require additional precautions to prevent hazardous discharges from the powders. Test methods included in this standard may be used in association with other performance requirements, for example when a risk assessment has shown the minimum ignition energy of concern is less than 0,14 mJ, charging currents are greater than 3,0 μA, or the ambient conditions are outside of the range specified in this standard. Compliance with the requirements specified in this standard does not necessarily ensure that electric shocks to personnel will not occur from FIBC during normal use. This second edition cancels and replaces the first edition, published in 2005, and constitutes a technical revision. The main changes with respect to the first edition are listed below: a) Adoption of a type classification system for FIBC based on four types: A, B, C and D. b) Guidance for safe use of FIBC in relation to hazardous areas and hazardous zones defined in IEC 60079-10-1 and IEC 60079-10-2 is added. c) Resistance to groundable points and electrical breakdown voltage measurements on FIBC shall be measured at low humidity only. d) Requirements for labelling FIBC are changed to improve clarity and ease of recognition by end users. e) Classification, performance requirements and guidance for safe use of inner liners in combination with FIBC are added. f) An informative annex giving guidance on test methods for quality control and inspection testing is added.

Need to identify, monitor and decipher standards?

COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.

Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!

Request your free, no-obligation live demo

I discover COBAZ