IEC 61347-1:2007
Lamp controlgear - Part 1: General and safety requirements
This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz.This second edition cancels and replaces the first edition published in 2000 and its Amendment 1 (2003). It constitutes a technical revision. The definition clause has been extended (rated no-load output voltage, controllable ballasts, control terminals, control signal). General requirements for lamp control gear which do not have their own enclosure have been added. The informative information (for ballasts in lamp standards) is now transformed into a normative requirement (in ballast standards). The test schedule has been minimised where possible, see 5.7 and Annex J. For printed circuit boards, the (non-) inflammability requirements have been specified. An Annex on conformity testing during manufacture has been added.
This part of IEC 61347 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This second edition cancels and replaces the first edition published in 2000 and its Amendment 1 (2003). It constitutes a technical revision. The definition clause has been extended (rated no-load output voltage, controllable ballasts, control terminals, control signal). General requirements for lamp control gear which do not have their own enclosure have been added. The informative information (for ballasts in lamp standards) is now transformed into a normative requirement (in ballast standards). The test schedule has been minimised where possible, see 5.7 and Annex J. For printed circuit boards, the (non-) inflammability requirements have been specified. An Annex on conformity testing during manufacture has been added.
IEC 61347-1:2015 specifies general and safety requirements for lamp controlgear for use on d.c. supplies up to 250 V and/or a.c. supplies up to 1 000 V at 50 Hz or 60 Hz. This third edition cancels and replaces the second edition published in 2007, Amendment 1:2010 and Amendment 2:2012. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: a) additional marking requirements; b) additional requirements for creepage distances and clearances: - for working voltages with operating frequencies up to 30 kHz; - for working voltages with higher operating frequencies than 30 kHz; - for impulse and resonance voltages ignition; - for basic, supplementary and reinforced insulation; - for insulation between circuits; - for coated or potted controlgear; c) modification of definition of ELV and FELV; d) modification of schematic drawing, showing the different controlgear classification and insulation requirements; e) scope extension; f) new Annex A: test to establish whether a conductive part is a live part which may cause an electric shock; g) new Annex M: creepage distances and clearances for controlgear where a higher degree of availability (impulse withstand category III) may be requested; h) new Annex Q: example for Up calculation; i) new Annex P: creepage distances and clearances and distance through isolation (DTI) for lamp controlgear which are protected against pollution by the use of coating or potting; j) new Annex R: concept of creepage distances and clearances. This publication is to be read in conjunction with theIEC 61347-2 series
COBAZ is the simple and effective solution to meet the normative needs related to your activity, in France and abroad.
Available by subscription, CObaz is THE modular solution to compose according to your needs today and tomorrow. Quickly discover CObaz!
Request your free, no-obligation live demo
I discover COBAZ